A randomized trial comparing dual axis rotational versus conventional coronary angiography in a population with a high prevalence of coronary artery disease.
Giuberti, Rafael S O; Caixeta, Adriano; Carvalho, Antônio C; Soares, Milton M; Abreu-Silva, Erlon O; Pestana, José O Medina; Silva Júnior, Hélio T; Vaz, Maria Lúcia; Généreux, Philippe; Fernandes, Rosley W A.
Afiliación
  • Giuberti RS; Hospital do Rim; Hospital São Paulo, Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, Brazil.
J Interv Cardiol ; 27(5): 456-64, 2014 Oct.
Article en En | MEDLINE | ID: mdl-25132588
OBJECTIVES: To compare the safety, radiation dose, and contrast volume between dual axis rotational coronary angiography (DARCA) and conventional coronary angiography (CCA). BACKGROUND: CCA is performed in multiple, predefined stationary views, at different angulations around the patient, for both the left and right coronary arteries. DARCA (AlluraXperSwing™, Philips, the Netherlands) involves a pre-set rotation of the C-arm around the patient and allows for the visualization of each coronary artery in different views, using a single automatic pump contrast injection. METHODS: From November 2012 to February 2013, 201 patients were randomly assigned to either CCA (n = 100) or DARCA (n = 101). Exclusion criteria included acute coronary syndrome (ACS), prior PCI or CABG. CCAs were performed in 4 acquisition runs for the left coronary artery and 2 to 3 acquisition runs for the right coronary artery, whereas DARCAs were performed in a single run for each coronary artery. RESULTS: Baseline demographics and clinical characteristics were similar for both groups. The overall prevalence of CAD was 77.6%. The DARCA group had a significant reduction in the amount of contrast, 60 ml (IQR: 52.5-71.5 ml) versus 76 ml (IQR: 68-87 ml), P < 0.0001; and radiation dose by Air Kerma, 269.5 mGy (IQR: 176-450.5) versus 542.1 mGy (IQR: 370.7-720.8), P < 0.0001. There were fewer patients requiring additional projections in the DARCA group: 54.0% versus 75.0%; P = 0.002. CONCLUSIONS: In a population with a high prevalence of CAD, DARCA was safe and resulted in a significant decrease in contrast volume and radiation dose.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Angiografía Coronaria Tipo de estudio: Clinical_trials / Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: J Interv Cardiol Asunto de la revista: CARDIOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Enfermedad de la Arteria Coronaria / Angiografía Coronaria Tipo de estudio: Clinical_trials / Observational_studies / Prevalence_studies / Risk_factors_studies Límite: Female / Humans / Male / Middle aged Idioma: En Revista: J Interv Cardiol Asunto de la revista: CARDIOLOGIA Año: 2014 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Estados Unidos