Your browser doesn't support javascript.
loading
Effect of patellar thickness on early results of total knee replacement with patellar resurfacing.
Lee, Qunn Jid; Yeung, Sze Tsun; Wong, Yiu Chung; Wai, Yuk Leung.
Afiliación
  • Lee QJ; Joint Replacement Center, Yan Chai Hospital, Tsuen Wan, Hong Kong SAR, China, leejasper@gmail.com.
Knee Surg Sports Traumatol Arthrosc ; 22(12): 3093-9, 2014 Dec.
Article en En | MEDLINE | ID: mdl-25145946
ABSTRACT

PURPOSE:

Patellar thickness is a concern in total knee replacement with patellar resurfacing because of the risk of patellar fracture or implant loosening. The aim of this study was to evaluate if patellar thickness is related to clinical outcome in the absence of patellar fracture or implant loosening.

METHODS:

Early results of 169 patients who underwent total knee replacement with patellar resurfacing were reviewed to assess the effect of patellar thickness on clinical outcome. The mean follow-up was 13 months. The range of motion, Knee Society Score, Function Score and WOMAC Score were assessed preoperatively, at day 0, 6 months and 1 year. Radiographs were assessed for patellar fracture or implant loosening.

RESULTS:

Thirty-one percent of all patients had preoperative thickness <21 mm. Seven percent had <12 mm residual thickness after patellar cut, all were female. Twenty-three percent had ≥1 mm increase of thickness after surgery. Radiographs did not show any patellar fracture or implant loosening. However, preoperative patellar thickness <21 mm had poorer gain in range of motion at 1 year. Preoperative range of motion had greater influence on postoperative range of motion than preoperative patellar thickness. Residual thickness <12 mm had lower gain in WOMAC score at 1 year and an increase in thickness ≥1 mm postoperatively was associated with lower gain in WOMAC score at 6 months.

CONCLUSIONS:

Early results of patellar resurfacing with preoperative thickness <21 mm or residual thickness <12 mm were found to be inferior even in the absence of patellar fracture or implant loosening. Conservative cutting resulting in 1 mm increase in thickness was also found to have inferior clinical results. LEVEL OF EVIDENCE II.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rótula / Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Articulación de la Rodilla Límite: Aged / Female / Humans / Male Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Asunto de la revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Año: 2014 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rótula / Artroplastia de Reemplazo de Rodilla / Osteoartritis de la Rodilla / Articulación de la Rodilla Límite: Aged / Female / Humans / Male Idioma: En Revista: Knee Surg Sports Traumatol Arthrosc Asunto de la revista: MEDICINA ESPORTIVA / TRAUMATOLOGIA Año: 2014 Tipo del documento: Article