Your browser doesn't support javascript.
loading
Red blood cell as a universal optoacoustic sensor for non-invasive temperature monitoring.
Petrova, Elena V; Oraevsky, Alexander A; Ermilov, Sergey A.
Afiliación
  • Petrova EV; TomoWave Laboratories, Inc. , 6550 Mapleridge St., Suite 124, Houston, Texas 77081-4629, USA.
  • Oraevsky AA; TomoWave Laboratories, Inc. , 6550 Mapleridge St., Suite 124, Houston, Texas 77081-4629, USA.
  • Ermilov SA; TomoWave Laboratories, Inc. , 6550 Mapleridge St., Suite 124, Houston, Texas 77081-4629, USA.
Appl Phys Lett ; 105(9): 094103, 2014 Sep 01.
Article en En | MEDLINE | ID: mdl-25316928
Optoacoustic (photoacoustic) temperature imaging could provide improved spatial resolution and temperature sensitivity as compared to other techniques of non-invasive thermometry used during thermal therapies for safe and efficient treatment of lesions. However, accuracy of the reported optoacoustic methods is compromised by biological variability and heterogeneous composition of tissues. We report our findings on the universal character of the normalized temperature dependent optoacoustic response (ThOR) in blood, which is invariant with respect to hematocrit at the isosbestic point of hemoglobin. The phenomenon is caused by the unique homeostatic compartmentalization of blood hemoglobin exclusively inside erythrocytes. On the contrary, the normalized ThOR in aqueous solutions of hemoglobin showed linear variation with respect to its concentration and was identical to that of blood when extrapolated to the hemoglobin concentration inside erythrocytes. To substantiate the conclusions, we analyzed optoacoustic images acquired from the samples of whole and diluted blood as well as hemoglobin solutions during gradual cooling from +37 to -15 °C. Our experimental methodology allowed direct observation and accurate measurement of the temperature of zero optoacoustic response, manifested as the sample's image faded into background and then reappeared in the reversed (negative) contrast. These findings provide a framework necessary for accurate correlation of measured normalized optoacoustic image intensity and local temperature in vascularized tissues independent of tissue composition.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Appl Phys Lett Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Appl Phys Lett Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos