Improvement of phosphor modeling based on the absorption of Stokes shifted light by a phosphor.
Opt Express
; 22 Suppl 5: A1237-42, 2014 Aug 25.
Article
en En
| MEDLINE
| ID: mdl-25322178
We have found that the emission spectrum of phosphors measured in the powder state differs from that measured for a single phosphor. When the emission spectrum of the powder state is adopted in an optical simulation, the simulated optical properties e.g., the correlated color temperature, color rendering index, and chromaticity coordinates, show a remarkable discrepancy from those of the fabricated LED package. However, the discrepancy is significantly improved when the emission spectrum from a low concentration of phosphor in a silicone binder is employed. We suggest that the discrepancy originates from the absorption of Stokes shifted light by a phosphor.