Your browser doesn't support javascript.
loading
Comparison of the accuracy of two conventional phenotypic methods and two MALDI-TOF MS systems with that of DNA sequencing analysis for correctly identifying clinically encountered yeasts.
Chao, Qiao-Ting; Lee, Tai-Fen; Teng, Shih-Hua; Peng, Li-Yun; Chen, Ping-Hung; Teng, Lee-Jene; Hsueh, Po-Ren.
Afiliación
  • Chao QT; Departments of Laboratory Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan.
  • Lee TF; Departments of Laboratory Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan; Department and Graduate Institute of Clinical Laboratory Sciences and Medical Biotechnology, National Taiwan University, Taipei, Taiwan.
  • Teng SH; Department of Graduate Institute of Biomedical Sciences, Chang Gung University, Tao-Yuan, Taiwan; Bruker Taiwan Co., Ltd., Taipei, Taiwan.
  • Peng LY; Departments of Laboratory Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan.
  • Chen PH; Departments of Laboratory Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan.
  • Teng LJ; Departments of Laboratory Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan; Department and Graduate Institute of Clinical Laboratory Sciences and Medical Biotechnology, National Taiwan University, Taipei, Taiwan.
  • Hsueh PR; Departments of Laboratory Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan; Departments of and Internal Medicine, National Taiwan University Hospital, National Taiwan University College of Medicine, Taipei, Taiwan.
PLoS One ; 9(10): e109376, 2014.
Article en En | MEDLINE | ID: mdl-25330370
ABSTRACT
We assessed the accuracy of species-level identification of two commercially available matrix-assisted laser desorption ionization-time of flight mass spectrometry (MALDI-TOF MS) systems (Bruker Biotyper and Vitek MS) and two conventional phenotypic methods (Phoenix 100 YBC and Vitek 2 Yeast ID) with that of rDNA gene sequencing analysis among 200 clinical isolates of commonly encountered yeasts. The correct identification rates of the 200 yeast isolates to species or complex (Candida parapsilosis complex, C. guilliermondii complex and C. rugosa complex) levels by the Bruker Biotyper, Vitek MS (using in vitro devices [IVD] database), Phoenix 100 YBC and Vitek 2 Yeast ID (Sabouraud's dextrose agar) systems were 92.5%, 79.5%, 89%, and 74%, respectively. An additional 72 isolates of C. parapsilosis complex and 18 from the above 200 isolates (30 in each of C. parapsilosis, C. metapsilosis, and C. orthopsilosis) were also evaluated separately. Bruker Biotyper system could accurately identify all C. parapsilosis complex to species level. Using Vitek 2 MS (IVD) system, all C. parapsilosis but none of C. metapsilosis, or C. orthopsilosis could be accurately identified. Among the 89 yeasts misidentified by the Vitek 2 MS (IVD) system, 39 (43.8%), including 27 C. orthopsilosis isolates, could be correctly identified Using the Vitek MS Plus SARAMIS database for research use only. This resulted in an increase in the rate of correct identification of all yeast isolates (87.5%) by Vitek 2 MS. The two species in C. guilliermondii complex (C. guilliermondii and C. fermentati) isolates were correctly identified by cluster analysis of spectra generated by the Bruker Biotyper system. Based on the results obtained in the current study, MALDI-TOF MS systems present a promising alternative for the routine identification of yeast species, including clinically commonly and rarely encountered yeast species and several species belonging to C. parapsilosis complex, C. guilliermondii complex, and C. rugosa complex.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fenotipo / Levaduras / Análisis de Secuencia de ADN / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Límite: Humans Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2014 Tipo del documento: Article País de afiliación: Taiwán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fenotipo / Levaduras / Análisis de Secuencia de ADN / Espectrometría de Masa por Láser de Matriz Asistida de Ionización Desorción Límite: Humans Idioma: En Revista: PLoS One Asunto de la revista: CIENCIA / MEDICINA Año: 2014 Tipo del documento: Article País de afiliación: Taiwán