Revision of a loose cementless short-stem threaded femoral component using a standard cementless stem in a canine hip arthroplasty.
Vet Comp Orthop Traumatol
; 28(1): 54-9, 2015.
Article
en En
| MEDLINE
| ID: mdl-25396223
A Helica short-stemmed femoral prosthesis that was identified as being loose one year after implantation was revised with a standard long stem cementless BFX femoral prosthesis. A double pelvic osteotomy was also performed to improve the orientation of the stable acetabular cup. Despite complete resorption of the femoral neck, and a large perforation of the lateral femoral cortex, the revision stem did not subside or rotate. The prosthetic joint did not dislocate. At re-evaluation two years after revision surgery, the prosthetic components were stable. Signs of bone ingrowth into the stem and cup were evident on radiographs. The dog had a seven percent greater thigh muscle girth in the limb implanted with the hip prosthesis compared to the contralateral limb, and was very active with no lameness.