Your browser doesn't support javascript.
loading
Far infrared laser polarimetry and far forward scattering diagnostics for the C-2 field reversed configuration plasmas.
Deng, B H; Kinley, J S; Knapp, K; Feng, P; Martinez, R; Weixel, C; Armstrong, S; Hayashi, R; Longman, A; Mendoza, R; Gota, H; Tuszewski, M.
Afiliación
  • Deng BH; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Kinley JS; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Knapp K; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Feng P; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Martinez R; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Weixel C; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Armstrong S; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Hayashi R; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Longman A; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Mendoza R; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Gota H; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
  • Tuszewski M; Tri Alpha Energy, Inc., P.O. Box 7010, Rancho Santa Margarita, California 92688, USA.
Rev Sci Instrum ; 85(11): 11D401, 2014 Nov.
Article en En | MEDLINE | ID: mdl-25430164
ABSTRACT
A two-chord far infrared (FIR) laser polarimeter for high speed sub-degree Faraday rotation measurements in the C-2 field reversed configuration experiment is described. It is based on high power proprietary FIR lasers with line width of about 330 Hz. The exceptionally low intrinsic instrument phase error is characterized with figures of merit. Significant toroidal magnetic field with rich dynamics is observed. Simultaneously obtained density fluctuation spectra by far forward scattering are presented.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos