Your browser doesn't support javascript.
loading
Reconstruction of 2D x-ray radiographs at the National Ignition Facility using pinhole tomography (invited).
Field, J E; Rygg, J R; Barrios, M A; Benedetti, L R; Döppner, T; Izumi, N; Jones, O; Khan, S F; Ma, T; Nagel, S R; Pak, A; Tommasini, R; Bradley, D K; Town, R P J.
Afiliación
  • Field JE; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Rygg JR; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Barrios MA; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Benedetti LR; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Döppner T; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Izumi N; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Jones O; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Khan SF; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Ma T; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Nagel SR; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Pak A; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Tommasini R; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Bradley DK; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
  • Town RP; Lawrence Livermore National Laboratory, Livermore, California 94550, USA.
Rev Sci Instrum ; 85(11): 11E503, 2014 Nov.
Article en En | MEDLINE | ID: mdl-25430345
ABSTRACT
Two-dimensional radiographs of imploding fusion capsules are obtained at the National Ignition Facility by projection through a pinhole array onto a time-gated framing camera. Parallax among images in the image array makes it possible to distinguish contributions from the capsule and from the backlighter, permitting correction of backlighter non-uniformities within the capsule radiograph. Furthermore, precise determination of the imaging system geometry and implosion velocity enables combination of multiple images to reduce signal-to-noise and discover new capsule features.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Rev Sci Instrum Año: 2014 Tipo del documento: Article País de afiliación: Estados Unidos