A feasibility study to determine the potential of in vivo detection of gadolinium by x-ray fluorescence (XRF) following gadolinium-based contrast-enhanced MRI.
Mostafaei, F; McNeill, F E; Chettle, D R; Noseworthy, M D.
Afiliación
  • Mostafaei F; Medical Physics and Applied Radiation Sciences, McMaster University, Hamilton, ON L8S 4K1, Canada.
Physiol Meas ; 36(1): N1-13, 2015 Jan.
Article en En | MEDLINE | ID: mdl-25501799
The feasibility of using a (109)Cd γ-ray induced K x-ray fluorescence (K-XRF) system for the in vivo detection of gadolinium (Gd) in bone has been investigated. The K-XRF bone measurement system employs an array of four detectors, and is normally used for the non-invasive study of bone lead levels. The system was used to measure bone simulating phantoms doped with varying levels of gadolinium and fixed amounts of sodium (Na), chlorine (Cl) and calcium (Ca). The detection limits for bare bone phantoms, using a source of activity 0.17 GBq, were determined to be 3.9 ppm and 6.5 ppm (µg Gd per gram phantom) for the Kα1 and Kα2 Gd x-ray peaks, respectively. This leads to an overall detection limit of 3.3 ppm (µg Gd per gram phantom). Layers of plastic were used to simulate overlying soft tissue and this permitted prediction of a detection limit, using the current strength of our radioisotope source, of 6.1 ppm to 8.6 ppm (µg Gd per gram phantom) for fingers with 2-4 mm of overlying tissue. With a new source of activity 5 GBq, we predict that this system could achieve a detection limit of 4-5.6 µg Gd g(-1) Ca. This is within the range of levels (2-30 µg Gd g(-1) Ca) previously found in the bone of patients receiving Gd based contrast imaging agents. The technique is promising and warrants further investigation.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría por Rayos X / Huesos / Imagen por Resonancia Magnética / Medios de Contraste / Gadolinio Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Physiol Meas Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Espectrometría por Rayos X / Huesos / Imagen por Resonancia Magnética / Medios de Contraste / Gadolinio Tipo de estudio: Diagnostic_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Physiol Meas Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Reino Unido