Your browser doesn't support javascript.
loading
Safety of poly (ethylene glycol)-coated perfluorodecalin-filled poly (lactide-co-glycolide) microcapsules following intravenous administration of high amounts in rats.
Ferenz, Katja B; Waack, Indra N; Laudien, Julia; Mayer, Christian; Broecker-Preuss, Martina; Groot, Herbert de; Kirsch, Michael.
Afiliación
  • Ferenz KB; University of Duisburg-Essen, Institute for Physiological Chemistry, University Hospital Essen, Hufelandstr. 55, Essen 45122, Germany.
  • Waack IN; University of Duisburg-Essen, Institute for Physiological Chemistry, University Hospital Essen, Hufelandstr. 55, Essen 45122, Germany.
  • Laudien J; University of Duisburg-Essen, Institute for Physiological Chemistry, University Hospital Essen, Hufelandstr. 55, Essen 45122, Germany.
  • Mayer C; University of Duisburg-Essen, Institute for Physical Chemistry, CeNIDE, Universitaetsstr. 5, Essen 45141, Germany.
  • Broecker-Preuss M; Department of Endocrinology and Metabolism Illnesses, Division of Laboratory Research, University of Duisburg-Essen, University Hospital Essen, Hufelandstr. 55, Essen 45122, Germany.
  • Groot Hd; University of Duisburg-Essen, Institute for Physiological Chemistry, University Hospital Essen, Hufelandstr. 55, Essen 45122, Germany.
  • Kirsch M; University of Duisburg-Essen, Institute for Physiological Chemistry, University Hospital Essen, Hufelandstr. 55, Essen 45122, Germany.
Results Pharma Sci ; 4: 8-18, 2014.
Article en En | MEDLINE | ID: mdl-25756002
ABSTRACT
The host response against foreign materials designates the biocompatibility of intravenously administered microcapsules and thus, widely affects their potential for subsequent clinical use as artificial oxygen/drug carriers. Therefore, body distribution and systemic parameters, as well as markers of inflammation and indicators of organ damage were carefully evaluated after administration of short-chained poly (vinyl alcohol, (PVA)) solution or poly (ethylene glycol (PEG))-shielded perfluorodecalin-filled poly (d,l-lactide-co-glycolide, PFD-filled PLGA) microcapsules into Wistar rats. Whereas PVA infusion was well tolerated, all animals survived the selected dose of 1247 mg microcapsules/kg body weight but showed marked toxicity (increased enzyme activities, rising pro-inflammatory cytokines and complement factors) and developed a mild metabolic acidosis. The observed hypotension emerging immediately after start of capsule infusion was transient and mean arterial blood pressure restored to baseline within 70 min. Microcapsules accumulated in spleen and liver (but not in other organs) and partly occluded hepatic microcirculation reducing sinusoidal perfusion rate by about 20%. Intravenous infusion of high amounts of PFD-filled PLGA microcapsules was tolerated temporarily but associated with severe side effects such as hypotension and organ damage. Short-chained PVA displays excellent biocompatibility and thus, can be utilized as emulsifier for the preparation of drug carriers designed for intravenous use.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Results Pharma Sci Año: 2014 Tipo del documento: Article País de afiliación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Results Pharma Sci Año: 2014 Tipo del documento: Article País de afiliación: Alemania