Your browser doesn't support javascript.
loading
[Remote results of reimplantation of the aortic valve in patients with ascending aortic aneurysm accompanied by aortic insufficiency].
Cherniavskii, A M; Al'sov, S A; Sirota, D A; Khvan, D S; Liashenko, M M; Ponomarev, D N; Kadyrbaev, D Zh.
Afiliación
  • Cherniavskii AM; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
  • Al'sov SA; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
  • Sirota DA; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
  • Khvan DS; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
  • Liashenko MM; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
  • Ponomarev DN; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
  • Kadyrbaev DZh; Centre for Surgery of the Aorta, Coronary and Peripheral Arteries, Novosibirsk Scientific Research Institute for Circulatory Pathology named after Academician E.N. Meshalkin under the RF Public Health Ministry, Novosibirsk, Russia.
Angiol Sosud Khir ; 21(1): 141-7, 2015.
Article en Ru | MEDLINE | ID: mdl-25757177
ABSTRACT
Valve-sparing operations on the aorta has recently been gaining ever increasing popularity due to more detailed study of physiology of the aortic root, as well as promising mid- and long-term results. The world practice uses various techniques making it possible to remove both ascending aortic aneurysm and aortic valve insufficiency. The authors herein describe and analyse their experience in performing reimplantation of the aortic valve in patients with ascending aortic aneurysm and concomitant aortic insufficiency. Specialists of the clinic of the Novosibirsk Scientific Research Institute for Circulatory Pathology during the period from 2003 to 2013 performed a total of 77 operations of reimplantation of the aortic valve in patients with ascending aortic aneurysm and pronounced aortic valve insufficiency. The majority of patients were men (57 males and 20 females), mean age 53.1±12.2 years (range 21-72). 80% of cases had NYHA functional class II-III circulatory insufficiency (degree 2.3±0.7). Preoperative examination revealed in the majority of patients (97.4%) moderate-to-severe aortic valve insufficiency and ascending aortic aneurysm. All patients underwent reimplantation of the aortic valve. The duration of artificial circulation amounted to 202.4±33 minutes, with the average time of aortic occlusion being 164±28 min. Accompanying procedures (annuloplasty of the mitral valve and/or coronary aortic bypass grafting) were performed in 12 (15.6%) cases. Additional plasty of valvular cusps was carried out in 9 (11.7%) patients, with rethoracotomy required in 5 (6.4%) cases due to haemorrhage. The average period of follow up amounted to 53.3±8.5 (3-115) months. During this time total survival amounted to 91%, with freedom from aortic valve prosthetic repair equalling 93%. The obtained findings suggest that aortic valve reimplantation into the prosthesis is a safe intervention and associated with a comparatively low level of operative lethality. Moderate aortic insufficiency at discharge is a predicting factor for repeat surgical intervention, i.e. prosthetic repair of the aortic valve. No association between the preoperative degree of aortic insufficiency, root diameter and durability of the reimplanted valve was revealed.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Aórtica / Aneurisma de la Aorta Torácica / Implantación de Prótesis de Válvulas Cardíacas / Implantación de Prótesis Vascular Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Ru Revista: Angiol Sosud Khir Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Rusia
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Insuficiencia de la Válvula Aórtica / Aneurisma de la Aorta Torácica / Implantación de Prótesis de Válvulas Cardíacas / Implantación de Prótesis Vascular Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: Ru Revista: Angiol Sosud Khir Asunto de la revista: CARDIOLOGIA Año: 2015 Tipo del documento: Article País de afiliación: Rusia