Your browser doesn't support javascript.
loading
Physician-initiated prospective Italian Registry of carotid stenting with the C-Guard mesh-stent: the IRON-Guard registry. Rationale and design.
Setacci, C; Speziale, F; De Donato, G; Sirignano, P; Setacci, F; Capoccia, L; Galzerano, G; Mansour, W.
Afiliación
  • Setacci C; Vascular and Endovascular Surgery Unit, Policlinico "Santa Maria alle Scotte", University of Siena, Siena, Italy - setacci@unisi.it.
J Cardiovasc Surg (Torino) ; 56(5): 787-91, 2015 Oct.
Article en En | MEDLINE | ID: mdl-25996843
ABSTRACT
According to the World Health Organization, every year, 5 million peoples die for stroke and another 5 million are permanently disabled. Although there are many causes of acute stroke, a common treatable cause of acute stroke is atheromatous narrowing at the carotid bifurcation. Carotid endarterectomy is still the standard of car, even if carotid artery stenting (CAS) has become an effective, less invasive alterantive. Unfortunately, CAS procedure is not yet perfect; regardless the use of an embolic protection device (EPD), percutaneous treatment has been correlated with a risk of cerebral ischemic events related to distal embolization. The objective of the IRON-Guard Registry is to evaluate the clinical outcome of treatment by means of stenting with the C-Guard (InspireMD, Boston, MA, USA) in subjects requiring CAS due to significant extracranial carotid artery stenosis with a physician-initiated, Italian, prospective, multicenter, single-arm study. A total of 200 enrolled subjects divided over different centers are planned to be enrolled. CAS will performed by implanting of C-Guard stent. Procedure will be performed according to the physician's standard of care. Standard procedures will be followed based on the Instructions for Use, for the C-Guard device of Inspire. The primary endpoint of this study is the 30-day rate of major adverse events (MAE), defined as the cumulative incidence of any periprocedural (≤30 days postprocedure) death, stroke or myocardial infarction. Secondary endpoints are rate of late ipsilateral stroke (31 through 365 days), system technical success, device malfunctions, major adverse events (MAEs), serious device-related and procedure-related adverse events, target lesion revascularization, and in-stent restenosis rates.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Proyectos de Investigación / Stents / Sistema de Registros / Estenosis Carotídea / Angioplastia Tipo de estudio: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans País/Región como asunto: Europa Idioma: En Revista: J Cardiovasc Surg (Torino) Año: 2015 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Proyectos de Investigación / Stents / Sistema de Registros / Estenosis Carotídea / Angioplastia Tipo de estudio: Clinical_trials / Diagnostic_studies / Etiology_studies / Observational_studies / Risk_factors_studies Límite: Humans País/Región como asunto: Europa Idioma: En Revista: J Cardiovasc Surg (Torino) Año: 2015 Tipo del documento: Article