Your browser doesn't support javascript.
loading
GGEMS-Brachy: GPU GEant4-based Monte Carlo simulation for brachytherapy applications.
Lemaréchal, Yannick; Bert, Julien; Falconnet, Claire; Després, Philippe; Valeri, Antoine; Schick, Ulrike; Pradier, Olivier; Garcia, Marie-Paule; Boussion, Nicolas; Visvikis, Dimitris.
Afiliación
  • Lemaréchal Y; LaTIM, UMR1101, INSERM, CHRU Brest, France.
  • Bert J; LaTIM, UMR1101, INSERM, CHRU Brest, France.
  • Falconnet C; Service de radiothérapie, CHRU Brest, France.
  • Després P; Département de radio-oncologie and Centre de recherche du CHU de Québec, Québec QC, Canada.
  • Valeri A; Départment de physique, de genie physique et d'optique and Centre de recherche sur le cancer, Université Laval, Québec QC, Canada.
  • Schick U; Départment de physique, de genie physique et d'optique and Centre de recherche sur le cancer, Université Laval, Québec QC, Canada.
  • Pradier O; Service d'urologie, CHRU Brest, France.
  • Garcia MP; LaTIM, UMR1101, INSERM, CHRU Brest, France.
  • Boussion N; Service de radiothérapie, CHRU Brest, France.
  • Visvikis D; LaTIM, UMR1101, INSERM, CHRU Brest, France.
Phys Med Biol ; 60(13): 4987-5006, 2015 Jul 07.
Article en En | MEDLINE | ID: mdl-26061230
ABSTRACT
In brachytherapy, plans are routinely calculated using the AAPM TG43 formalism which considers the patient as a simple water object. An accurate modeling of the physical processes considering patient heterogeneity using Monte Carlo simulation (MCS) methods is currently too time-consuming and computationally demanding to be routinely used. In this work we implemented and evaluated an accurate and fast MCS on Graphics Processing Units (GPU) for brachytherapy low dose rate (LDR) applications. A previously proposed Geant4 based MCS framework implemented on GPU (GGEMS) was extended to include a hybrid GPU navigator, allowing navigation within voxelized patient specific images and analytically modeled (125)I seeds used in LDR brachytherapy. In addition, dose scoring based on track length estimator including uncertainty calculations was incorporated. The implemented GGEMS-brachy platform was validated using a comparison with Geant4 simulations and reference datasets. Finally, a comparative dosimetry study based on the current clinical standard (TG43) and the proposed platform was performed on twelve prostate cancer patients undergoing LDR brachytherapy. Considering patient 3D CT volumes of 400 × 250 × 65 voxels and an average of 58 implanted seeds, the mean patient dosimetry study run time for a 2% dose uncertainty was 9.35 s (≈500 ms 10(-6) simulated particles) and 2.5 s when using one and four GPUs, respectively. The performance of the proposed GGEMS-brachy platform allows envisaging the use of Monte Carlo simulation based dosimetry studies in brachytherapy compatible with clinical practice. Although the proposed platform was evaluated for prostate cancer, it is equally applicable to other LDR brachytherapy clinical applications. Future extensions will allow its application in high dose rate brachytherapy applications.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Dosis de Radiación / Algoritmos / Planificación de la Radioterapia Asistida por Computador / Braquiterapia Tipo de estudio: Health_economic_evaluation / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Phys Med Biol Año: 2015 Tipo del documento: Article País de afiliación: Francia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Neoplasias de la Próstata / Dosis de Radiación / Algoritmos / Planificación de la Radioterapia Asistida por Computador / Braquiterapia Tipo de estudio: Health_economic_evaluation / Prognostic_studies Límite: Humans / Male Idioma: En Revista: Phys Med Biol Año: 2015 Tipo del documento: Article País de afiliación: Francia