Your browser doesn't support javascript.
loading
Investigating effects of hydroxypropyl methylcellulose (HPMC) molecular weight grades on lag time of press-coated ethylcellulose tablets.
Patadia, Riddhish; Vora, Chintan; Mittal, Karan; Mashru, Rajashree.
Afiliación
  • Patadia R; a Pharmacy Department, Faculty of Technology and Engineering , The Maharaja Sayajirao University of Baroda , Kalabhavan, Vadodara , Gujarat , India.
  • Vora C; a Pharmacy Department, Faculty of Technology and Engineering , The Maharaja Sayajirao University of Baroda , Kalabhavan, Vadodara , Gujarat , India.
  • Mittal K; a Pharmacy Department, Faculty of Technology and Engineering , The Maharaja Sayajirao University of Baroda , Kalabhavan, Vadodara , Gujarat , India.
  • Mashru R; a Pharmacy Department, Faculty of Technology and Engineering , The Maharaja Sayajirao University of Baroda , Kalabhavan, Vadodara , Gujarat , India.
Pharm Dev Technol ; 21(7): 794-802, 2016 Nov.
Article en En | MEDLINE | ID: mdl-26100758
The research undertaken exemplifies the effects of hydroxypropyl methylcellulose (HPMC) molecular weight (MW) grades of on lag time of press-coated ethylcellulose (EC) tablets. The formulation comprised an immediate release core (containing prednisone as a model drug) surrounded by compression coating with variegated EC-HPMC blends. Five selected HPMC grades (E5, E15, E50, K100LV and K4M) were explored at three different concentrations (10% w/w, 20% w/w and 30% w/w in outer coat) to understand their effects on lag time and drug release. In vitro drug release testing demonstrated that, with increase in concentration of E5 and E15, up to 30% w/w, the mean lag time decreased progressively; whereas with remaining grades, the mean lag time initially decreased up to 20% w/w level and thereafter increased for 30% w/w level. Importantly, with increase in HPMC concentration in the outer coat, the variability in lag time (%RSD; n = 6) was decreased for each of E5, E15 and E50, whereas increased for K100LV and K4M. In general, the variability in lag time was increased with increase in HPMC MW at studied concentration levels. Markedly, tablets with 30% w/w K4M in outer coat exhibited slight premature release (before the rupture of outer coat) along with high variability in lag time. Overall, the study concluded that low MW HPMCs (E5, E15 and E50) were found rather efficient than higher MW HPMCs for developing robust EC-based press-coated pulsatile release formulations where precise lag time followed by sharp burst release is desired.
Asunto(s)
Palabras clave
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Comprimidos / Celulosa / Materiales Biocompatibles Revestidos / Derivados de la Hipromelosa Idioma: En Revista: Pharm Dev Technol Asunto de la revista: FARMACIA Año: 2016 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Comprimidos / Celulosa / Materiales Biocompatibles Revestidos / Derivados de la Hipromelosa Idioma: En Revista: Pharm Dev Technol Asunto de la revista: FARMACIA Año: 2016 Tipo del documento: Article País de afiliación: India Pais de publicación: Reino Unido