Your browser doesn't support javascript.
loading
Influence of Pre-Storage Irradiation on the Oxidative Stress Markers, Membrane Integrity, Size and Shape of the Cold Stored Red Blood Cells.
Antosik, Adam; Czubak, Kamila; Gajek, Arkadiusz; Marczak, Agnieszka; Glowacki, Rafal; Borowczyk, Kamila; Zbikowska, Halina Malgorzata.
Afiliación
  • Antosik A; Department of General Biochemistry, Faculty of Biology and Environmental Protection, University of Lodz, Lodz, Poland.
  • Czubak K; Department of General Biochemistry, Faculty of Biology and Environmental Protection, University of Lodz, Lodz, Poland.
  • Gajek A; Department of Thermobiology, Faculty of Biology and Environmental Protection, University of Lodz, Lodz, Poland.
  • Marczak A; Department of Thermobiology, Faculty of Biology and Environmental Protection, University of Lodz, Lodz, Poland.
  • Glowacki R; Department of Environmental Chemistry, University of Lodz, Lodz, Poland.
  • Borowczyk K; Department of Environmental Chemistry, University of Lodz, Lodz, Poland.
  • Zbikowska HM; Department of General Biochemistry, Faculty of Biology and Environmental Protection, University of Lodz, Lodz, Poland.
Transfus Med Hemother ; 42(3): 140-8, 2015 May.
Article en En | MEDLINE | ID: mdl-26195927
ABSTRACT

BACKGROUND:

To investigate the extent of oxidative damage and changes in morphology of manually isolated red blood cells (RBCs) from whole blood, cold stored (up to 20 days) in polystyrene tubes and subjected to pre-storage irradiation (50 Gy) and to compare the properties of SAGM-preserved RBCs stored under experimental conditions (polystyrene tubes) with RBCs from standard blood bag storage.

METHODS:

The percentage of hemolysis as well as the extracellular activity of LDH, thiobarbituric acid-reactive substances, reduced glutathione (GSH), and total antioxidant capacity (TAC) were measured. Changes in the topology of RBC membrane, shape, and size were evaluated by flow cytometry and judged against microscopy images.

RESULTS:

Irradiation caused significant LDH release as well as increased hemolysis and lipid peroxidation, GSH depletion, and reduction of TAC. Prolonged storage of irradiated RBCs resulted in phosphatidylserine exposure on the cell surface. By day 20, approximately 60% of RBCs displayed non-discoid shape. We did not notice significant differences in percentage of altered cells and cell volume between RBCs exposed to irradiation and those not exposed.

CONCLUSION:

Irradiation of RBC transfusion units with a dose of 50 Gy should be avoided. For research purposes such as studying the role of antioxidants, storage of small volumes of RBCs derived from the same donor would be more useful, cheaper, and blood-saving.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Transfus Med Hemother Año: 2015 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Transfus Med Hemother Año: 2015 Tipo del documento: Article País de afiliación: Polonia