CT Metal Artifact Reduction in the Spine: Can an Iterative Reconstruction Technique Improve Visualization?
Kotsenas, A L; Michalak, G J; DeLone, D R; Diehn, F E; Grant, K; Halaweish, A F; Krauss, A; Raupach, R; Schmidt, B; McCollough, C H; Fletcher, J G.
Afiliación
  • Kotsenas AL; From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota Kotsenas.amy@mayo.edu.
  • Michalak GJ; From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota.
  • DeLone DR; From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota.
  • Diehn FE; From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota.
  • Grant K; Siemens Medical Solutions (K.G., A.F.H.), Malvern, Pennsylvania.
  • Halaweish AF; Siemens Medical Solutions (K.G., A.F.H.), Malvern, Pennsylvania.
  • Krauss A; Siemens Healthcare (A.K., R.R., B.S.), Forchheim, Germany.
  • Raupach R; Siemens Healthcare (A.K., R.R., B.S.), Forchheim, Germany.
  • Schmidt B; Siemens Healthcare (A.K., R.R., B.S.), Forchheim, Germany.
  • McCollough CH; From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota.
  • Fletcher JG; From the Department of Radiology (A.L.K., G.J.M., D.R.D., F.E.D., C.H.M., J.G.F.), Mayo Clinic, Rochester, Minnesota.
AJNR Am J Neuroradiol ; 36(11): 2184-90, 2015 Nov.
Article en En | MEDLINE | ID: mdl-26251433
BACKGROUND AND PURPOSE: Metal-related artifacts from spine instrumentation can obscure relevant anatomy and pathology. We evaluated the ability of CT images reconstructed with and without iterative metal artifact reduction to visualize critical anatomic structures in postoperative spines and assessed the potential for implementation into clinical practice. MATERIALS AND METHODS: We archived CT projection data in patients with instrumented spinal fusion. CT images were reconstructed by using weighted filtered back-projection and iterative metal artifact reduction. Two neuroradiologists evaluated images in the region of spinal hardware and assigned a score for the visualization of critical anatomic structures by using soft-tissue and bone windows (critical structures totally obscured, n = 0; anatomic recognition with high diagnostic confidence, n = 5). Using bone windows, we measured the length of the most pronounced linear artifacts. For each patient, neuroradiologists made recommendations regarding the optimal use of iterative metal artifact reduction and its impact on diagnostic confidence. RESULTS: Sixty-eight patients met the inclusion criteria. Visualization of critical soft-tissue anatomic structures was significantly improved by using iterative metal artifact reduction compared with weighted filtered back-projection (median, 1 ± 1.5 versus 3 ± 1.3, P < .001), with improvement in the worst visualized anatomic structure in 88% (60/68) of patients. There was not significant improvement in visualization of critical osseous structures. Linear metal artifacts were reduced from 29 to 11 mm (P < .001). In 87% of patients, neuroradiologists recommended reconstructing iterative metal artifact reduction images instead of weighted filtered back-projection images, with definite improvement in diagnostic confidence in 32% (22/68). CONCLUSIONS: Iterative metal artifact reduction improves visualization of critical soft-tissue structures in patients with spinal hardware. Routine generation of these images in addition to routine weighted filtered back-projection is recommended.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis e Implantes / Columna Vertebral / Interpretación de Imagen Radiográfica Asistida por Computador / Tomografía Computarizada por Rayos X / Artefactos Tipo de estudio: Guideline Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Año: 2015 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Prótesis e Implantes / Columna Vertebral / Interpretación de Imagen Radiográfica Asistida por Computador / Tomografía Computarizada por Rayos X / Artefactos Tipo de estudio: Guideline Límite: Adult / Aged / Female / Humans / Male / Middle aged Idioma: En Revista: AJNR Am J Neuroradiol Año: 2015 Tipo del documento: Article Pais de publicación: Estados Unidos