Development of dispersive XAFS system for analysis of time-resolved spatial distribution of electrode reaction.
Katayama, Misaki; Miyahara, Ryota; Watanabe, Toshiki; Yamagishi, Hirona; Yamashita, Shohei; Kizaki, Terue; Sugawara, Yoshimi; Inada, Yasuhiro.
Afiliación
  • Katayama M; Department of Applied Chemistry, Ritsumeikan University, Kusatsu 525-8577, Japan.
  • Miyahara R; Department of Applied Chemistry, Ritsumeikan University, Kusatsu 525-8577, Japan.
  • Watanabe T; Department of Applied Chemistry, Ritsumeikan University, Kusatsu 525-8577, Japan.
  • Yamagishi H; Department of Applied Chemistry, Ritsumeikan University, Kusatsu 525-8577, Japan.
  • Yamashita S; Department of Applied Chemistry, Ritsumeikan University, Kusatsu 525-8577, Japan.
  • Kizaki T; Kohzu Precision Co. Ltd, Kawasaki 215-8521, Japan.
  • Sugawara Y; Kohzu Precision Co. Ltd, Kawasaki 215-8521, Japan.
  • Inada Y; Department of Applied Chemistry, Ritsumeikan University, Kusatsu 525-8577, Japan.
J Synchrotron Radiat ; 22(5): 1227-32, 2015 Sep.
Article en En | MEDLINE | ID: mdl-26289274
Apparatus for a technique based on the dispersive optics of X-ray absorption fine structure (XAFS) has been developed at beamline BL-5 of the Synchrotron Radiation Center of Ritsumeikan University. The vertical axis of the cross section of the synchrotron light is used to disperse the X-ray energy using a cylindrical polychromator and the horizontal axis is used for the spatially resolved analysis with a pixel array detector. The vertically dispersive XAFS (VDXAFS) instrument was designed to analyze the dynamic changeover of the inhomogeneous electrode reaction of secondary batteries. The line-shaped X-ray beam is transmitted through the electrode sample, and then the dispersed transmitted X-rays are detected by a two-dimensional detector. An array of XAFS spectra in the linear footprint of the transmitted X-ray on the sample is obtained with the time resolution of the repetition frequency of the detector. Sequential measurements of the space-resolved XAFS data are possible with the VDXAFS instrument. The time and spatial resolutions of the VDXAFS instrument depend on the flux density of the available X-ray beam and the size of the light source, and they were estimated as 1 s and 100 µm, respectively. The electrode reaction of the LiFePO4 lithium ion battery was analyzed during the constant current charging process and during the charging process after potential jumping.