Simplification of immune adherence hemagglutination test for detection of rabies antibodies in human serum.
Rev Inst Med Trop Sao Paulo ; 31(5): 341-5, 1989.
Article en En | MEDLINE | ID: mdl-2629063
ABSTRACT
In the present work the immune adherence hemagglutination test (IAHA) was standardized in a simplified procedure. This test showed good reproducibility, better than the classical mice serum neutralization test (SN). The tests showed high correlation degree high titers in one test corresponded to high titers in the other one, and the same occurred with low titers. The IAHA test is extremely simple, fast to perform, and of low cost when compared to tests such as SN or indirect immunofluorescence (IIF). It also proved to be useful in less sophisticated laboratories or even as a screening test for the titration of rabies antibodies.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Virus de la Rabia / Reacción de Inmunoadherencia / Pruebas de Neutralización / Anticuerpos Antivirales Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Rev Inst Med Trop Sao Paulo Año: 1989 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Virus de la Rabia / Reacción de Inmunoadherencia / Pruebas de Neutralización / Anticuerpos Antivirales Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: Rev Inst Med Trop Sao Paulo Año: 1989 Tipo del documento: Article