Your browser doesn't support javascript.
loading
Development and validation of a direct-comparison method for cardiac (123)I-metaiodobenzylguanidine washout rates derived from late 3-hour and 4-hour imaging.
Okuda, Koichi; Nakajima, Kenichi; Sugino, Shuichi; Kirihara, Yumiko; Matsuo, Shinro; Taki, Junichi; Hashimoto, Mitsumasa; Kinuya, Seigo.
Afiliación
  • Okuda K; Department of Physics, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Kahoku, Ishikawa, 920-0293, Japan. okuda@kanazawa-med.ac.jp.
  • Nakajima K; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Sugino S; Department of Radiology, Okayama Kyokuto Hospital, 567-1 Kurata, Okayama, Okayama, 441-8570, Japan.
  • Kirihara Y; FUJIFILM RI Pharma Co., Ltd., 14-1, kyobashi 2-Chome, Chuo-Ku, Tokyo, 104-0031, Japan.
  • Matsuo S; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Taki J; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
  • Hashimoto M; Department of Physics, Kanazawa Medical University, 1-1 Daigaku, Uchinada, Kahoku, Ishikawa, 920-0293, Japan.
  • Kinuya S; Department of Nuclear Medicine, Kanazawa University Hospital, 13-1 Takara-machi, Kanazawa, Ishikawa, 920-8641, Japan.
Eur J Nucl Med Mol Imaging ; 43(2): 319-325, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26298280
PURPOSE: The washout rate (WR) has been used in (123)I-metaiodobenzylguanidine (MIBG) imaging to evaluate cardiac sympathetic innervation. However, WR varies depending on the time between the early and late MIBG scans. Late scans are performed at either 3 or 4 hours after injection of MIBG. The aim of this study was to directly compare the WR at 3 hours (WR3h) with the WR at 4 hours (WR4h). METHODS: We hypothesized that the cardiac count would reduce linearly between the 3-hour and 4-hour scans. A linear regression model for cardiac counts at two time-points was generated. We enrolled a total of 96 patients who underwent planar (123)I-MIBG scintigraphy early (15 min) and during the late phase at both 3 and 4 hours. Patients were randomly divided into two groups: a model-creation group (group 1) and a clinical validation group (group 2). Cardiac counts at 15 minutes (countearly), 3 hours (count3h) and 4 hours (count4h) were measured. Cardiac count4h was mathematically estimated using the linear regression model from countearly and count3h. RESULTS: In group 1, the actual cardiac count4h/countearly was highly significantly correlated with count3h/countearly (r = 0.979). In group 2, the average estimated count4h was 92.8 ± 31.9, and there was no significant difference between this value and the actual count4h (91.9 ± 31.9). Bland-Altman analysis revealed a small bias of -0.9 with 95 % limits of agreement of -6.2 and +4.3. WR4h calculated using the estimated cardiac count4h was comparable to the actual WR4h (24.3 ± 9.6 % vs. 25.1 ± 9.7 %, p = ns). Bland-Altman analysis and the intraclass correlation coefficient showed that there was excellent agreement between the estimated and actual WR4h. CONCLUSION: The linear regression model that we used accurately estimated cardiac count4h using countearly and count3h. Moreover, WR4h that was mathematically calculated using the estimated count4h was comparable to the actual WR4h.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Interpretación de Imagen Asistida por Computador / Radiofármacos / 3-Yodobencilguanidina / Tomografía de Emisión de Positrones / Imagen de Perfusión Miocárdica Tipo de estudio: Evaluation_studies / Observational_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Eur J Nucl Med Mol Imaging Asunto de la revista: MEDICINA NUCLEAR Año: 2016 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Algoritmos / Interpretación de Imagen Asistida por Computador / Radiofármacos / 3-Yodobencilguanidina / Tomografía de Emisión de Positrones / Imagen de Perfusión Miocárdica Tipo de estudio: Evaluation_studies / Observational_studies Límite: Aged / Aged80 / Female / Humans / Male Idioma: En Revista: Eur J Nucl Med Mol Imaging Asunto de la revista: MEDICINA NUCLEAR Año: 2016 Tipo del documento: Article País de afiliación: Japón Pais de publicación: Alemania