Your browser doesn't support javascript.
loading
Evaluation of a rapid method for the simultaneous quantification of ribavirin, sofosbuvir and its metabolite in rat plasma by UPLC-MS/MS.
Shi, Xiaojun; Zhu, Dedong; Lou, Jie; Zhu, Bo; Hu, Ai-rong; Gan, Dongmei.
Afiliación
  • Shi X; Department of Hepatopathy, Ningbo No.2 Hospital, Ningbo 315000, China.
  • Zhu D; Department of Hepatopathy, Ningbo No.2 Hospital, Ningbo 315000, China.
  • Lou J; Digestive Department, Ningbo No.2 Hospital, Ningbo 315000, China.
  • Zhu B; Pharmaceutical Preparation Section, Ningbo No.2 Hospital, Ningbo 315000, China.
  • Hu AR; Department of Hepatopathy, Ningbo No.2 Hospital, Ningbo 315000, China. Electronic address: 21466738@qq.com.
  • Gan D; Department of Paediatrics, Ningbo Women and Children's Hospital, Ningbo 315000, China. Electronic address: 109315536@qq.com.
Article en En | MEDLINE | ID: mdl-26363369
A rapid and sensitive ultra performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method for the determination of ribavirin, sofosbuvir and its metabolite GS-331007 in rat plasma was established. The analytes and the internal standard (midazolam) were separated on an Acquity UPLC BEH C18 chromatography column (2.1mm×50mm, 1.7µm) using gradient elution with a mobile phase of acetonitrile and 0.1% formic acid in water at a flow rate of 0.4mL/min. The detection was performed on a triple quadrupole tandem mass spectrometer by multiple reaction monitoring (MRM) mode to monitor the precursor-to-product ion transitions of m/z 245.1→113.1 for ribavirin, m/z 530.3→243.1 for sofosbuvir, m/z 261.5→113.1 for GS-331007 and m/z 326.2→291.1 for midazolam (IS) using a positive electrospray ionization interface. The method was validated over a concentration range of 5-1000ng/mL for ribavirin, 10-2000ng/mL for sofosbuvir and 10-2000ng/mL for GS-331007. Total time for each chromatograph was 3.0min. The intra- and inter-day precision and accuracy of the quality control samples at low, medium, and high concentration levels exhibited relative standard deviations (RSD) <10.0% and the accuracy values ranged from -10.6% to 11.6%. The method was successfully applied to a pharmacokinetic study of ribavirin, sofosbuvir and GS-331007 in rats.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Antivirales / Ribavirina / Cromatografía Liquida / Espectrometría de Masas en Tándem / Sofosbuvir Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2015 Tipo del documento: Article País de afiliación: China Pais de publicación: Países Bajos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Antivirales / Ribavirina / Cromatografía Liquida / Espectrometría de Masas en Tándem / Sofosbuvir Límite: Animals Idioma: En Revista: J Chromatogr B Analyt Technol Biomed Life Sci Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2015 Tipo del documento: Article País de afiliación: China Pais de publicación: Países Bajos