Your browser doesn't support javascript.
loading
Low-Cost High-Performance MRI.
Sarracanie, Mathieu; LaPierre, Cristen D; Salameh, Najat; Waddington, David E J; Witzel, Thomas; Rosen, Matthew S.
Afiliación
  • Sarracanie M; MGH/A.A. Martinos Center for Biomedical Imaging, 149 13th St, Suite 2301, Charlestown MA 02129, USA.
  • LaPierre CD; Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA.
  • Salameh N; MGH/A.A. Martinos Center for Biomedical Imaging, 149 13th St, Suite 2301, Charlestown MA 02129, USA.
  • Waddington DEJ; Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA.
  • Witzel T; MGH/A.A. Martinos Center for Biomedical Imaging, 149 13th St, Suite 2301, Charlestown MA 02129, USA.
  • Rosen MS; Department of Physics, Harvard University, 17 Oxford St, Cambridge, MA 02138, USA.
Sci Rep ; 5: 15177, 2015 Oct 15.
Article en En | MEDLINE | ID: mdl-26469756
Magnetic Resonance Imaging (MRI) is unparalleled in its ability to visualize anatomical structure and function non-invasively with high spatial and temporal resolution. Yet to overcome the low sensitivity inherent in inductive detection of weakly polarized nuclear spins, the vast majority of clinical MRI scanners employ superconducting magnets producing very high magnetic fields. Commonly found at 1.5-3 tesla (T), these powerful magnets are massive and have very strict infrastructure demands that preclude operation in many environments. MRI scanners are costly to purchase, site, and maintain, with the purchase price approaching $1 M per tesla (T) of magnetic field. We present here a remarkably simple, non-cryogenic approach to high-performance human MRI at ultra-low magnetic field, whereby modern under-sampling strategies are combined with fully-refocused dynamic spin control using steady-state free precession techniques. At 6.5 mT (more than 450 times lower than clinical MRI scanners) we demonstrate (2.5 × 3.5 × 8.5) mm(3) imaging resolution in the living human brain using a simple, open-geometry electromagnet, with 3D image acquisition over the entire brain in 6 minutes. We contend that these practical ultra-low magnetic field implementations of MRI (<10 mT) will complement traditional MRI, providing clinically relevant images and setting new standards for affordable (<$50,000) and robust portable devices.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline / Health_economic_evaluation Idioma: En Revista: Sci Rep Año: 2015 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Guideline / Health_economic_evaluation Idioma: En Revista: Sci Rep Año: 2015 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Reino Unido