Your browser doesn't support javascript.
loading
The reliability of a segmentation methodology for assessing intramuscular adipose tissue and other soft-tissue compartments of lower leg MRI images.
Karampatos, Sarah; Papaioannou, Alexandra; Beattie, Karen A; Maly, Monica R; Chan, Adrian; Adachi, Jonathan D; Pritchard, Janet M.
Afiliación
  • Karampatos S; Department of Medicine, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada. karampatos@hhsc.ca.
  • Papaioannou A; Juravinski Research Centre, Geriatric Education and Research in the Aging Sciences (GERAS) Centre, 88 Maplewood Avenue, Hamilton, ON, L8M 1W9, Canada. karampatos@hhsc.ca.
  • Beattie KA; Department of Rehabilitation Sciences, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada. karampatos@hhsc.ca.
  • Maly MR; Department of Medicine, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada.
  • Chan A; Juravinski Research Centre, Geriatric Education and Research in the Aging Sciences (GERAS) Centre, 88 Maplewood Avenue, Hamilton, ON, L8M 1W9, Canada.
  • Adachi JD; Department of Biostatistics and Epidemiology, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada.
  • Pritchard JM; Department of Medicine, McMaster University, 1280 Main St W, Hamilton, ON, L8S 4L8, Canada.
MAGMA ; 29(2): 237-44, 2016 Apr.
Article en En | MEDLINE | ID: mdl-26702939
ABSTRACT

OBJECTIVE:

Determine the reliability of a magnetic resonance (MR) image segmentation protocol for quantifying intramuscular adipose tissue (IntraMAT), subcutaneous adipose tissue, total muscle and intermuscular adipose tissue (InterMAT) of the lower leg. MATERIALS AND

METHODS:

Ten axial lower leg MRI slices were obtained from 21 postmenopausal women using a 1 Tesla peripheral MRI system. Images were analyzed using sliceOmatic™ software. The average cross-sectional areas of the tissues were computed for the ten slices. Intra-rater and inter-rater reliability were determined and expressed as the standard error of measurement (SEM) (absolute reliability) and intraclass coefficient (ICC) (relative reliability).

RESULTS:

Intra-rater and inter-rater reliability for IntraMAT were 0.991 (95% confidence interval [CI] 0.978-0.996, p < 0.05) and 0.983 (95% CI 0.958-9.993, p < 0.05), respectively. For the other soft tissue compartments, the ICCs were all >0.90 (p < 0.05). The absolute intra-rater and inter-rater reliability (expressed as SEM) for segmenting IntraMAT were 22.19 mm(2) (95% CI 16.97-32.04) and 78.89 mm(2) (95% CI 60.36-113.92), respectively.

CONCLUSION:

This is a reliable segmentation protocol for quantifying IntraMAT and other soft-tissue compartments of the lower leg. A standard operating procedure manual is provided to assist users, and SEM values can be used to estimate sample size and determine confidence in repeated measurements in future research.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reconocimiento de Normas Patrones Automatizadas / Imagen por Resonancia Magnética / Tejido Adiposo / Músculo Esquelético / Diabetes Mellitus Tipo 2 / Pierna Tipo de estudio: Diagnostic_studies Límite: Aged / Aged80 / Female / Humans Idioma: En Revista: MAGMA Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article País de afiliación: Canadá

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Reconocimiento de Normas Patrones Automatizadas / Imagen por Resonancia Magnética / Tejido Adiposo / Músculo Esquelético / Diabetes Mellitus Tipo 2 / Pierna Tipo de estudio: Diagnostic_studies Límite: Aged / Aged80 / Female / Humans Idioma: En Revista: MAGMA Asunto de la revista: DIAGNOSTICO POR IMAGEM Año: 2016 Tipo del documento: Article País de afiliación: Canadá