Automated pressure map segmentation for quantifying phalangeal kinetics during cylindrical gripping.
Sinsel, Erik W; Gloekler, Daniel S; Wimer, Bryan M; Warren, Christopher M; Wu, John Z; Buczek, Frank L.
Afiliación
  • Sinsel EW; National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA. Electronic address: ESinsel@cdc.gov.
  • Gloekler DS; National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA; Present address: University of Pittsburgh Medical Center (UPMC) Hamot, 201 State Street, Erie, PA 16550, USA.
  • Wimer BM; National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA.
  • Warren CM; National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA.
  • Wu JZ; National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA.
  • Buczek FL; National Institute for Occupational Safety and Health (NIOSH), 1095 Willowdale Road MS 2027, Morgantown, WV 26505, USA; Present address: Lake Erie College of Osteopathic Medicine (LECOM), 1858 West Grandview Blvd, Erie, PA 16509, USA.
Med Eng Phys ; 38(2): 72-9, 2016 Feb.
Article en En | MEDLINE | ID: mdl-26709291
ABSTRACT
Inverse dynamics models used to investigate musculoskeletal disorders associated with handle gripping require accurate phalangeal kinetics. Cylindrical handles wrapped with pressure film grids have been used in studies of gripping kinetics. We present a method fusing six degree-of-freedom hand kinematics and a kinematic calibration of a cylinder-wrapped pressure film. Phalanges are modeled as conic frusta and projected onto the pressure grid, automatically segmenting the pressure map into regions of interest (ROIs). To demonstrate the method, segmented pressure maps are presented from two subjects with substantially different hand length and body mass, gripping cylinders 50 and 70 mm in diameter. For each ROI, surface-normal force vectors were summed to create a reaction force vector and center of pressure location. Phalangeal force magnitudes for a data sample were similar to that reported in previous studies. To evaluate our method, a surrogate was designed for each handle such that when modeled as a phalanx it would generate a ROI around the cells under its supports; the classification F-score was above 0.95 for both handles. Both the human subject results and the surrogate evaluation suggest that the approach can be used to automatically segment the pressure map for quantifying phalangeal kinetics of the fingers during cylindrical gripping.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Presión / Fuerza de la Mano / Falanges de los Dedos de la Mano Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Med Eng Phys Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Presión / Fuerza de la Mano / Falanges de los Dedos de la Mano Tipo de estudio: Prognostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Med Eng Phys Asunto de la revista: BIOFISICA / ENGENHARIA BIOMEDICA Año: 2016 Tipo del documento: Article