Your browser doesn't support javascript.
loading
Synergistic effect of up-flow constructed wetland and microbial fuel cell for simultaneous wastewater treatment and energy recovery.
Oon, Yoong-Ling; Ong, Soon-An; Ho, Li-Ngee; Wong, Yee-Shian; Dahalan, Farrah Aini; Oon, Yoong-Sin; Lehl, Harvinder Kaur; Thung, Wei-Eng.
Afiliación
  • Oon YL; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Ong SA; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia. Electronic address: ongsoonan@yahoo.com.
  • Ho LN; School of Materials Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Wong YS; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Dahalan FA; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Oon YS; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Lehl HK; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
  • Thung WE; School of Environmental Engineering, Universiti Malaysia Perlis, 02600 Arau, Perlis, Malaysia.
Bioresour Technol ; 203: 190-7, 2016 Mar.
Article en En | MEDLINE | ID: mdl-26724550
ABSTRACT
This study demonstrated a successful operation of up-flow constructed wetland-microbial fuel cell (UFCW-MFC) in wastewater treatment and energy recovery. The goals of this study were to investigate the effect of circuit connection, organic loading rates, and electrode spacing on the performance of wastewater treatment and bioelectricity generation. The average influent of COD, NO3(-) and NH4(+) were 624 mg/L, 142 mg/L, 40 mg/L, respectively and their removal efficiencies (1 day HRT) were 99%, 46%, and 96%, respectively. NO3(-) removal was relatively higher in the closed circuit system due to lower dissolved oxygen in the system. Despite larger electrode spacing, the voltage outputs from Anode 2 (A2) (30 cm) and Anode 3 (A3) (45 cm) were higher than from Anode 1 (A1) (15 cm) as a result of insufficient fuel supply to A1. The maximum power density and Coulombic efficiency were obtained at A2, which were 93 mW/m(3) and 1.42%, respectively.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fuentes de Energía Bioeléctrica / Purificación del Agua / Conservación de los Recursos Energéticos / Humedales Idioma: En Revista: Bioresour Technol Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2016 Tipo del documento: Article País de afiliación: Malasia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fuentes de Energía Bioeléctrica / Purificación del Agua / Conservación de los Recursos Energéticos / Humedales Idioma: En Revista: Bioresour Technol Asunto de la revista: ENGENHARIA BIOMEDICA Año: 2016 Tipo del documento: Article País de afiliación: Malasia