Your browser doesn't support javascript.
loading
Three-dimensional isotropic T2-weighted fast spin-echo (VISTA) ankle MRI versus two-dimensional fast spin-echo T2-weighted sequences for the evaluation of anterior talofibular ligament injury.
Park, H J; Lee, S Y; Park, N H; Rho, M H; Chung, E C; Park, J H; Park, S J.
Afiliación
  • Park HJ; Department of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Republic of Korea.
  • Lee SY; Department of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Republic of Korea.
  • Park NH; Department of Radiology, Myongji Hospital, Seonam University College of Medicine, Republic of Korea. Electronic address: radiology11@hanmail.net.
  • Rho MH; Department of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Republic of Korea.
  • Chung EC; Department of Radiology, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Republic of Korea.
  • Park JH; Department of Orthopaedic Surgery, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Republic of Korea.
  • Park SJ; Department of Orthopaedic Surgery, Sungkyunkwan University School of Medicine, Kangbuk Samsung Hospital, Republic of Korea.
Clin Radiol ; 71(4): 349-55, 2016 Apr.
Article en En | MEDLINE | ID: mdl-26774370
ABSTRACT

AIM:

To compare the performance of axial images of the ankle joint on three-dimensional (3D) volume isotropic turbo spin echo acquisition (VISTA) with that of two-dimensional (2D) fast spin echo (FSE) T2-weighted images for the diagnosis of anterior talofibular ligament (ATFL) injury. MATERIALS AND

METHODS:

This retrospective study included 101 patients who underwent both 2D FSE T2-weighted and 3D VISTA magnetic resonance imaging (MRI) of the ankle. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of both sequences were measured. The anatomical identification score and diagnostic performances of both sequences were evaluated by two radiologists. The diagnostic performances of 3D VISTA and 2D FSE images were analysed in terms of sensitivity, specificity, and accuracy for diagnosing ATFL injury. Surgically or clinically confirmed diagnoses were used as reference standards.

RESULTS:

The margin sharpness scores on 3D VISTA were significantly inferior to those of 2D FSE (p<0.001). Other scores (entire length, entire width) were not significantly different between the two imaging methods. The SNRs and CNRs of 3D VISTA were significantly higher than those of 2D FSE (p<0.001). When diagnoses were classified as normal and abnormal, the specificity of the 3D VISTA images for the diagnosis of ATFL injury was 95.7%, significantly superior to 2D FSE (84.3-85.7%). There were no significant differences between 3D VISTA and 2D FSE images in sensitivity or accuracy for diagnosis (p=0.227-1.000), with the exception of accuracy by reader 1 (p=0.039).

CONCLUSION:

3D VISTA imaging has a diagnostic performance comparable to that of 2D FSE for the diagnosis of ATFL injury, although 3D VISTA is inferior to 2D FSE for the evaluation of margin sharpness. Replacing axial and coronal images with 3D VISTA can save imaging time without negatively impacting the diagnostic ability for ATFL injury.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Traumatismos del Tobillo / Ligamentos Laterales del Tobillo / Imagenología Tridimensional / Articulación del Tobillo Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Radiol Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Traumatismos del Tobillo / Ligamentos Laterales del Tobillo / Imagenología Tridimensional / Articulación del Tobillo Tipo de estudio: Diagnostic_studies / Guideline / Observational_studies / Prognostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Child / Female / Humans / Male / Middle aged Idioma: En Revista: Clin Radiol Año: 2016 Tipo del documento: Article