Interlaboratory Evaluation of Ultraviolet Radiation Emissions from Compact Fluorescent Lamps.
Photochem Photobiol
; 92(2): 348-354, 2016 03.
Article
en En
| MEDLINE
| ID: mdl-26814835
There have been many recent reports regarding the potential risks of UV emissions from compact fluorescent lamps (CFLs). In some of these reports, the robustness of the measurements was difficult to discern. We conducted round-robin measurements, involving three lamp manufacturers and two government research laboratories to gather reliable data on the UV emissions from commercially available CFLs. The initial sample of lamps consisted of 71 spiral-shaped CFLs purchased from local retailers. From the initial sample, 14 "high UV emitting" CFLs were chosen for further evaluation. We compared the UV emissions at a distance of 20 cm with the UV exposure limits (ELs) published by the International Commission on Non-ionizing Radiation Protection (ICNIRP). We found that the allowable exposure time for measured lamps ranged from 21 to 415 h. This indicates that the emissions would not exceed the short-term ELs that have been established by the ICNIRP for healthy individuals. We also evaluated the potential long-term risk and found it to be insignificant. There was a large variation in the UV emissions found, even for lamps from a single package, indicating that it is impossible to predict the UV output of a CFL based on its physical appearance and model designation.
Texto completo:
1
Colección:
01-internacional
Base de datos:
MEDLINE
Tipo de estudio:
Prognostic_studies
Idioma:
En
Revista:
Photochem Photobiol
Año:
2016
Tipo del documento:
Article
Pais de publicación:
Estados Unidos