Your browser doesn't support javascript.
loading
Preparation of a novel sorptive stir bar based on vinylpyrrolidone-ethylene glycol dimethacrylate monolithic polymer for the simultaneous extraction of diazepam and nordazepam from human plasma.
Torabizadeh, Mahsa; Talebpour, Zahra; Adib, Nuoshin; Aboul-Enein, Hassan Y.
Afiliación
  • Torabizadeh M; Department of Chemistry, Faculty of Physics & Chemistry, University of Alzahra, Vanak, Tehran, Iran.
  • Talebpour Z; Department of Chemistry, Faculty of Physics & Chemistry, University of Alzahra, Vanak, Tehran, Iran.
  • Adib N; Food and Drug Research Center, Ministry of Health, Tehran, Iran.
  • Aboul-Enein HY; Department of Pharmaceutical and Medicinal Chemistry, Pharmaceutical and Drug Industries Research Division, National Research Centre, Giza, Egypt.
J Sep Sci ; 39(7): 1316-25, 2016 Apr.
Article en En | MEDLINE | ID: mdl-26840622
ABSTRACT
A new monolithic coating based on vinylpyrrolidone-ethylene glycol dimethacrylate polymer was introduced for stir bar sorptive extraction. The polymerization step was performed using different contents of monomer, cross-linker and porogenic solvent, and the best formulation was selected. The quality of the prepared vinylpyrrolidone-ethylene glycol dimethacrylate stir bars was satisfactory, demonstrating good repeatability within batch (relative standard deviation < 3.5%) and acceptable reproducibility between batches (relative standard deviation < 6.0%). The prepared stir bar was utilized in combination with ultrasound-assisted liquid desorption, followed by high-performance liquid chromatography with ultraviolet detection for the simultaneous determination of diazepam and nordazepam in human plasma samples. To optimize the extraction step, a three-level, four-factor, three-block Box-Behnken design was applied. Under the optimum conditions, the analytical performance of the proposed method displayed excellent linear dynamic ranges for diazepam (36-1200 ng/mL) and nordazepam (25-1200 ng/mL), with correlation coefficients of 0.9986 and 0.9968 and detection limits of 12 and 10 ng/mL, respectively. The intra- and interday recovery ranged from 93 to 106%, and the relative standard deviations were less than 6%. Finally, the proposed method was successfully applied to the analysis of diazepam and nordazepam at their therapeutic levels in human plasma. The novelty of this study is the improved polarity of the stir bar coating and its application for the simultaneous extraction of diazepam and its active metabolite, nordazepam in human plasma sample. The method was more rapid than previously reported stir bar sorptive extraction techniques based on monolithic coatings, and exhibited lower detection limits in comparison with similar methods for the determination of diazepam and nordazepam in biological fluids.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pirrolidinonas / Cromatografía Líquida de Alta Presión / Nordazepam / Diazepam / Metacrilatos Límite: Humans Idioma: En Revista: J Sep Sci Año: 2016 Tipo del documento: Article País de afiliación: Irán

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Pirrolidinonas / Cromatografía Líquida de Alta Presión / Nordazepam / Diazepam / Metacrilatos Límite: Humans Idioma: En Revista: J Sep Sci Año: 2016 Tipo del documento: Article País de afiliación: Irán