Highly-sensitive Eu(3+) ratiometric thermometers based on excited state absorption with predictable calibration.
Souza, Adelmo S; Nunes, Luiz A O; Silva, Ivan G N; Oliveira, Fernando A M; da Luz, Leonis L; Brito, Hermi F; Felinto, Maria C F C; Ferreira, Rute A S; Júnior, Severino A; Carlos, Luís D; Malta, Oscar L.
Afiliación
  • Souza AS; Departamento de Química Fundamental-CCEN-UFPE, Cidade Universitária, Recife-PE, 50670-901, Brazil. adelmosaturnino@hotmail.com.
  • Nunes LA; Instituto de Física de São Carlos, Universidade de São Paulo - USP, CEP 13560-970, São Carlos, SP, Brazil.
  • Silva IG; Instituto de Química, Universidade de São Paulo, 05508-900 São Paulo, SP, Brazil.
  • Oliveira FA; Instituto de Física de São Carlos, Universidade de São Paulo - USP, CEP 13560-970, São Carlos, SP, Brazil.
  • da Luz LL; Departamento de Química Fundamental-CCEN-UFPE, Cidade Universitária, Recife-PE, 50670-901, Brazil. adelmosaturnino@hotmail.com.
  • Brito HF; Instituto de Química, Universidade de São Paulo, 05508-900 São Paulo, SP, Brazil.
  • Felinto MC; Centro de Química do Meio Ambiente, Instituto de Pesquisas Energéticas e Nucleares, Av. Prof. Lineu Prestes, 2242, 05508-000 São Paulo, SP, Brazil.
  • Ferreira RA; Department of Physics and CICECO Aveiro Institute of Materials, University of Aveiro, 3810-193 Aveiro, Portugal. lcarlos@ua.pt.
  • Júnior SA; Departamento de Química Fundamental-CCEN-UFPE, Cidade Universitária, Recife-PE, 50670-901, Brazil. adelmosaturnino@hotmail.com.
  • Carlos LD; Department of Physics and CICECO Aveiro Institute of Materials, University of Aveiro, 3810-193 Aveiro, Portugal. lcarlos@ua.pt.
  • Malta OL; Departamento de Química Fundamental-CCEN-UFPE, Cidade Universitária, Recife-PE, 50670-901, Brazil. adelmosaturnino@hotmail.com.
Nanoscale ; 8(9): 5327-33, 2016 Mar 07.
Article en En | MEDLINE | ID: mdl-26883124
ABSTRACT
Temperature measurements ranging from a few degrees to a few hundreds of Kelvin are of great interest in the fields of nanomedicine and nanotechnology. Here, we report a new ratiometric luminescent thermometer using thermally excited state absorption of the Eu(3+) ion. The thermometer is based on the simple Eu(3+) energy level structure and can operate between 180 and 323 K with a relative sensitivity ranging from 0.7 to 1.7% K(-1). The thermometric parameter is defined as the ratio between the emission intensities of the (5)D0 → (7)F4 transition when the (5)D0 emitting level is excited through the (7)F2 (physiological range) or (7)F1 (down to 180 K) level. Nano and microcrystals of Y2O3Eu(3+) were chosen as a proof of concept of the operational principles in which both excitation and detection are within the first biological transparent window. A novel and of paramount importance aspect is that the calibration factor can be calculated from the Eu(3+) emission spectrum avoiding the need for new calibration procedures whenever the thermometer operates in different media.

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Tipo de estudio: Diagnostic_studies / Prognostic_studies / Risk_factors_studies Idioma: En Revista: Nanoscale Año: 2016 Tipo del documento: Article País de afiliación: Brasil