ABSTRACT

OBJECTIVE:

To summarize application of rafting K-wires technique for tibial plateau fractures.

METHODS:

From January 2013 to January 2015,45 patients with tibial plateau fractures were treated by locking plate with rafting K-wires, including 33 males and 12 females with an average of 44.2 years old ranging from 22 to 56 years old. According to Schatzker classification, 6 cases were type II, 8 were type Ill, 4 were type IV, 4 were type V, and 5 were type VI. Allogeneic bone graft were performed for bone defects. All patients were fixed with two to five K-wires. Part of weight loading were encouraged at 3 months after operation,and full weight-loading were done at 5 months after operation. Postoperative complications were observed,and Rasmussen clinical and radiological assessment were used to evaluate clinical results.

RESULTS:

All Patients were followed up from 10 to 23 months with average of 14 months. According to Rasmussen clinical and radiological assessment, clinical scores 23.58 ± 6.33, radiological scores were 14.00 ± 6.33; and excellent and good rates were 82.2% and 77.8% respectively. Four patients occurred severe osteoporosis and collapse of articular surface; 5 patients occurred traumatic arthritis.

CONCLUSION:

Rafting K-wires technique with anatomized armor plate could effective fix and support platform collapse and joint bone fragments, increase support surface area and reduce postoperative reduction loss rate.
Asunto(s)
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas de la Tibia / Hilos Ortopédicos / Fijación Interna de Fracturas Límite: Adult / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Gu Shang Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2015 Tipo del documento: Article
Buscar en Google
Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fracturas de la Tibia / Hilos Ortopédicos / Fijación Interna de Fracturas Límite: Adult / Female / Humans / Male / Middle aged Idioma: Zh Revista: Zhongguo Gu Shang Asunto de la revista: ORTOPEDIA / TRAUMATOLOGIA Año: 2015 Tipo del documento: Article