Your browser doesn't support javascript.
loading
Comparison of the Orbscan II topographer and the iTrace aberrometer for the measurements of keratometry and corneal diameter in myopic patients.
Chen, Yao; Xia, Xiaobo.
Afiliación
  • Chen Y; Department of Ophthalmology, Xiangya Hospital, Central South University, Changsha, Hunan, China.
  • Xia X; Department of Ophthalmology, Xiangya Hospital, Central South University, Changsha, Hunan, China. xbxia21@163.com.
BMC Ophthalmol ; 16: 33, 2016 Mar 31.
Article en En | MEDLINE | ID: mdl-27029933
ABSTRACT

BACKGROUND:

The purpose of this study was to compare corneal power and horizontal corneal diameter (white-to-white [WTW] distance) readings obtained by the Orbscan II topographer and the iTrace aberrometer.

METHODS:

Keratometry readings in the flat (Kf) and steep (Ks) meridians and WTW distance were measured with the Orbscan II and iTrace systems in 100 myopic patients. Statistical evaluation was performed using the paired t test, Pearson correlation, and Bland-Altman analysis for comparison of measurement techniques.

RESULTS:

The mean keratometry values with the Orbscan II and iTrace were 43.16 ± 1.44 and 42.64 ± 1.43 diopter (D), respectively (P < 0.0001). The mean WTW distance measurements with the Orbscan II and iTrace were 11.57 ± 0.34 and 11.33 ± 0.36 mm, respectively (P < 0.0001). For the measurement of corneal power, the 95 % limits of agreement (LoA) between the Orbscan II and iTrace were - 0.21 to 1.21 D for the flat meridian and - 0.15 to 1.25 D for the steep meridian. For the measurement of WTW distance, the range of the 95 % LoA between the two devices was 0.47 mm.

CONCLUSIONS:

For some clinical applications, the keratometry and WTW distance measurements obtained by the Orbscan II topographer and the iTrace aberrometer differed greatly and therefore were not interchangeable. TRIAL REGISTRATION Clinical trials number ChiCTR-OCS-14005077 (August 2nd, 2014).
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Córnea / Topografía de la Córnea / Aberrometría / Miopía Límite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Córnea / Topografía de la Córnea / Aberrometría / Miopía Límite: Adolescent / Adult / Child / Female / Humans / Male Idioma: En Revista: BMC Ophthalmol Asunto de la revista: OFTALMOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: China