Your browser doesn't support javascript.
loading
Performance of Three Single Instrument Systems in the Preparation of Long Oval Canals.
Coelho, Beatriz Serrato; Amaral, Rodrigo Otavio Jatahy Ferreira do; Leonardi, Denise Piotto; Marques-da-Silva, Bruno; Silva-Sousa, Yara Teresinha Corrêa; Carvalho, Fredson Marcio Acris de; Baratto-Filho, Flares.
Afiliación
  • Coelho BS; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
  • Amaral RO; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
  • Leonardi DP; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
  • Marques-da-Silva B; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
  • Silva-Sousa YT; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
  • Carvalho FM; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
  • Baratto-Filho F; Department of Dentistry, Positivo University, Curitiba, PR, Brazil.
Braz Dent J ; 27(2): 217-22, 2016.
Article en En | MEDLINE | ID: mdl-27058387
This study aimed to evaluate the performance of the Wave One, Easy ProDesign Logic and One Shape systems in the preparation of long oval root canals. Forty-two mandibular incisors were randomized into three groups: Group I, Wave One Primary (WO) (#25.08); Group II, Easy ProDesign Logic (EPL) (#25.06) and Group III, One Shape (OS) (#25.06). Micro-computed tomography scans were obtained pre- and post-preparation of the samples. Instrument fractures or loss of working length did not occur in any of the groups. There was a statistically significant difference in total root canal volume between the WO and EPL (p<0.05) and OS systems (p<0.05) The mean percentages of instrumented canal area in the middle thirds were 76.9% in the WO, 62.3% in the EPL and 71.8% in the OS (p>0.05). The OS system had the strongest correlation between volume increase and instrumented area (R=0.63). The WO, EPL and OS systems presented mean preparation times of 2.13 min, 0.54 min, and 2.21 min (p<0.05), respectively. All three systems enabled the safe preparation of long oval root canals. The WO system most effectively increased root canal volume, but it did not affect the instrumented areas. The OS system had the strongest correlation between volume increase and instrumented area, while the EPL system was the fastest.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Preparación del Conducto Radicular / Instrumentos Dentales Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Braz Dent J Asunto de la revista: ODONTOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Preparación del Conducto Radicular / Instrumentos Dentales Tipo de estudio: Clinical_trials Límite: Humans Idioma: En Revista: Braz Dent J Asunto de la revista: ODONTOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Brasil Pais de publicación: Brasil