Your browser doesn't support javascript.
loading
Platelet transfusion therapy in sub-Saharan Africa: bacterial contamination, recipient characteristics, and acute transfusion reactions.
Hume, Heather A; Ddungu, Henry; Angom, Racheal; Baluku, Hannington; Kajumbula, Henry; Kyeyune-Byabazaire, Dorothy; Orem, Jackson; Ramirez-Arcos, Sandra; Tobian, Aaron A R.
Afiliación
  • Hume HA; Centre Hospitalier Universitaire Ste-Justine, University of Montreal, Montreal, Québec, Canada.
  • Ddungu H; Uganda Cancer Institute.
  • Angom R; Uganda Cancer Institute.
  • Baluku H; College of Health Sciences, Makerere University.
  • Kajumbula H; College of Health Sciences, Makerere University.
  • Kyeyune-Byabazaire D; Uganda Blood Transfusion Service, Kampala, Uganda.
  • Orem J; Uganda Cancer Institute.
  • Ramirez-Arcos S; Canadian Blood Services, Ottawa, Ontario, Canada.
  • Tobian AA; Johns Hopkins University, Baltimore, Maryland.
Transfusion ; 56(8): 1951-9, 2016 08.
Article en En | MEDLINE | ID: mdl-27079627
BACKGROUND: Little data are available on bacterial contamination (BC) of platelet units or acute transfusion reactions to platelet transfusions (PTs) in sub-Saharan Africa (SSA). STUDY DESIGN AND METHODS: This prospective, observational study evaluated the rate of BC in whole blood-derived platelet units (WB-PUs), the utility of performing Gram stains to prevent septic reactions, characteristics of patients receiving PTs, and the rate of acute reactions associated with PTs at the Uganda Cancer Institute in Kampala, Uganda. An aliquot of each WB-PU studied was taken to perform Gram stains and culture using the Bactec 9120 instrument. Study participants were monitored for reactions. RESULTS: In total, 337 WB-PUs were evaluated for BC, of which 323 units were transfused in 151 transfusion episodes to 50 patients. The frequency of BC ranged from 0.3% to 2.1% (according to criteria used to define BC). The Gram stain had high specificity (99.1%) but low sensitivity to detect units with BC. The median platelet count before PT was 10,900 cells/µL (interquartile range, 6000-18,900 cells/µL). Overall, 78% of PTs were given to patients with no bleeding. Acute reactions occurred in 11 transfusion episodes, involving 13 WB-PUs, for a rate of 7.3% (95% confidence interval, 3.7%-12.7%) per transfusion episode. All recipients of units with positive bacterial cultures were receiving antibiotics at the time of transfusion; none experienced a reaction. CONCLUSIONS: The rate of BC observed in this study is lower than previously reported in SSA, but still remains a safety issue. Because Gram staining appears to be an ineffective screening tool, alternate methods should be explored to prevent transfusing bacterially contaminated platelets in sub-Saharan Africa.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones Bacterianas / Plaquetas / Transfusión de Plaquetas / Reacción a la Transfusión Tipo de estudio: Observational_studies Límite: Adolescent / Adult / Female / Humans / Male País/Región como asunto: Africa Idioma: En Revista: Transfusion Año: 2016 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Infecciones Bacterianas / Plaquetas / Transfusión de Plaquetas / Reacción a la Transfusión Tipo de estudio: Observational_studies Límite: Adolescent / Adult / Female / Humans / Male País/Región como asunto: Africa Idioma: En Revista: Transfusion Año: 2016 Tipo del documento: Article País de afiliación: Canadá Pais de publicación: Estados Unidos