Is Ultrasound Fusion a Reasonable Replacement for Computed Tomography in Guiding Abdominal Interventions?
Ahmed, Yasmine; Novak, Ronald D; Nakamoto, Dean; Azar, Nami.
Afiliación
  • Ahmed Y; University Hospitals, Case Medical Center, Cleveland, Ohio USA yasmine.ahmed@uhhospitals.org.
  • Novak RD; University Hospitals, Case Medical Center, Cleveland, Ohio USACase Western Reserve University School of Medicine, Cleveland, Ohio USA.
  • Nakamoto D; University Hospitals, Case Medical Center, Cleveland, Ohio USA.
  • Azar N; University Hospitals, Case Medical Center, Cleveland, Ohio USA.
J Ultrasound Med ; 35(6): 1131-41, 2016 Jun.
Article en En | MEDLINE | ID: mdl-27091917
ABSTRACT

OBJECTIVES:

To compare the diagnostic yield, complication rate, and procedure length of ultrasound fusion-guided liver biopsy to the diagnostic yield, complication rate, and procedure length of computed tomography (CT)-guided liver biopsy; to measure the average ionizing radiation dose that patients are exposed to during a typical CT-guided liver biopsy procedure; and to present relevant and interesting cases of ultrasound fusion-guided abdominal interventions to describe the efficacious use of the technology.

METHODS:

A retrospective analysis of 63 patients who had image-guided liver biopsies performed at our institution was completed. Patient records were divided into 2 groups according to the type of image guidance used during the procedure (ultrasound fusion versus CT), and data were compared by the χ(2) test, Student t test, and Mann-Whitney U test.

RESULTS:

The diagnostic yields and complication rates were not statistically significantly different between the modalities. The average procedure durations were significantly different ultrasound fusion-guided biopsy, 31.63 minutes; compared to CT-guided biopsy, 61.67 minutes (P = .003).

CONCLUSIONS:

Diagnostic yields and complication rates were comparable for ultrasound fusion and CT. However, the average procedure duration for an ultrasound fusion-guided liver biopsy was approximately half that of CT-guided liver biopsy, likely increasing both cost-effectiveness and patient satisfaction.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Tomografía Computarizada por Rayos X / Ultrasonografía Intervencional / Imagen Multimodal / Hígado Tipo de estudio: Guideline / Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Imagen por Resonancia Magnética / Tomografía Computarizada por Rayos X / Ultrasonografía Intervencional / Imagen Multimodal / Hígado Tipo de estudio: Guideline / Observational_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: J Ultrasound Med Año: 2016 Tipo del documento: Article