Your browser doesn't support javascript.
loading
Comparison of the Roche Cobas® 4800 HPV assay to Roche Amplicor for detection of high-risk human papillomavirus.
Phillips, S; Cornall, A M; Machalek, D A; Garland, S M; Bateson, D; Garefalakis, M; Tabrizi, S N.
Afiliación
  • Phillips S; Regional HPV Lab Net Reference Laboratory, Department of Microbiology and Infectious Diseases, The Royal Women's Hospital, Parkville, Victoria, Australia. sam.phillips@mcri.edu.au.
  • Cornall AM; Department of Microbiology and Infectious Diseases, The Royal Women's Hospital, Bio 21 Institute, Parkville, 3052, Australia. sam.phillips@mcri.edu.au.
  • Machalek DA; Murdoch Childrens Research Institute, Parkville, Victoria, 3052, Australia. sam.phillips@mcri.edu.au.
  • Garland SM; Regional HPV Lab Net Reference Laboratory, Department of Microbiology and Infectious Diseases, The Royal Women's Hospital, Parkville, Victoria, Australia.
  • Bateson D; Murdoch Childrens Research Institute, Parkville, Victoria, 3052, Australia.
  • Garefalakis M; Regional HPV Lab Net Reference Laboratory, Department of Microbiology and Infectious Diseases, The Royal Women's Hospital, Parkville, Victoria, Australia.
  • Tabrizi SN; Murdoch Childrens Research Institute, Parkville, Victoria, 3052, Australia.
Eur J Clin Microbiol Infect Dis ; 35(8): 1305-7, 2016 Aug.
Article en En | MEDLINE | ID: mdl-27177752
ABSTRACT
UNLABELLED Roche Amplicor HPV (AMP) had previously been used for detection of high-risk human papillomavirus (HR-HPV) in epidemiological and clinical studies. As this assay is no longer available, we compared its performance using PreservCyt samples from women aged of 18-24 years attending for routine cervical cytology screening to Roche Cobas® 4800 (Cobas) to determine if subsequent studies could continue using the Cobas assay. Overall 507 samples were tested on Cobas and compared to previous AMP results, with discrepant samples tested on Roche Linear Array.

RESULTS:

Overall, agreement between the Cobas and AMP for the presence of HR HPV types was very high (κ = 0.81) (95 % CI 0.76 - 0.87) with percentage agreement of 91.57 %. Cobas is comparable to AMP for the detection of HR-HPV types in a community recruited cohort of healthy women.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Papillomaviridae / Juego de Reactivos para Diagnóstico / Técnicas de Amplificación de Ácido Nucleico / Infecciones por Papillomavirus Tipo de estudio: Diagnostic_studies / Etiology_studies / Risk_factors_studies Límite: Adolescent / Adult / Female / Humans Idioma: En Revista: Eur J Clin Microbiol Infect Dis Asunto de la revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Australia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Papillomaviridae / Juego de Reactivos para Diagnóstico / Técnicas de Amplificación de Ácido Nucleico / Infecciones por Papillomavirus Tipo de estudio: Diagnostic_studies / Etiology_studies / Risk_factors_studies Límite: Adolescent / Adult / Female / Humans Idioma: En Revista: Eur J Clin Microbiol Infect Dis Asunto de la revista: DOENCAS TRANSMISSIVEIS / MICROBIOLOGIA Año: 2016 Tipo del documento: Article País de afiliación: Australia