Your browser doesn't support javascript.
loading
Bayesian Solutions for Handling Uncertainty in Survival Extrapolation.
Negrín, Miguel A; Nam, Julian; Briggs, Andrew H.
Afiliación
  • Negrín MA; Health Economics and Health Technology Assessment, Institute of Health & Wellbeing, University of Glasgow, Glasgow, UK (MAN, JN, AHB).
  • Nam J; Department of Quantitative Methods, University of Las Palmas de G.C., Las Palmas de G.C., Spain (MAN).
  • Briggs AH; Health Economics and Health Technology Assessment, Institute of Health & Wellbeing, University of Glasgow, Glasgow, UK (MAN, JN, AHB).
Med Decis Making ; 37(4): 367-376, 2017 05.
Article en En | MEDLINE | ID: mdl-27281336
OBJECTIVE: Survival extrapolation using a single, best-fit model ignores 2 sources of model uncertainty: uncertainty in the true underlying distribution and uncertainty about the stability of the model parameters over time. Bayesian model averaging (BMA) has been used to account for the former, but it can also account for the latter. We investigated BMA using a published comparison of the Charnley and Spectron hip prostheses using the original 8-year follow-up registry data. METHODS: A wide variety of alternative distributions were fitted. Two additional distributions were used to address uncertainty about parameter stability: optimistic and skeptical. The optimistic (skeptical) model represented the model distribution with the highest (lowest) estimated probabilities of survival but reestimated using, as prior information, the most optimistic (skeptical) parameter estimated for intermediate follow-up periods. Distributions were then averaged assuming the same posterior probabilities for the optimistic, skeptical, and noninformative models. Cost-effectiveness was compared using both the original 8-year and extended 16-year follow-up data. RESULTS: We found that all models obtained similar revision-free years during the observed period. In contrast, there was variability over the decision time horizon. Over the observed period, we detected considerable uncertainty in the shape parameter for Spectron. After BMA, Spectron was cost-effective at a threshold of £20,000 with 93% probability, whereas the best-fit model was 100%; by contrast, with a 16-year follow-up, it was 0%. CONCLUSIONS: This case study casts doubt on the ability of the single best-fit model selected by information criteria statistics to adequately capture model uncertainty. Under this scenario, BMA weighted by posterior probabilities better addressed model uncertainty. However, there is still value in regularly updating health economic models, even where decision uncertainty is low.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Análisis de Supervivencia / Teorema de Bayes / Análisis Costo-Beneficio / Toma de Decisiones Clínicas Tipo de estudio: Health_economic_evaluation / Prognostic_studies Aspecto: Patient_preference Límite: Humans Idioma: En Revista: Med Decis Making Año: 2017 Tipo del documento: Article Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Análisis de Supervivencia / Teorema de Bayes / Análisis Costo-Beneficio / Toma de Decisiones Clínicas Tipo de estudio: Health_economic_evaluation / Prognostic_studies Aspecto: Patient_preference Límite: Humans Idioma: En Revista: Med Decis Making Año: 2017 Tipo del documento: Article Pais de publicación: Estados Unidos