A test experiment has shown that the number of ultracold neutrons (UCN) of one polarization state, transmitted through a 100 µm Al foil when placed in a 5 T magnetic field, is greater by 3.8 times. The increased transmission is due to the higher velocity of the UCN passing through the foil.