[A Novel, Less Invasive Protection Method for Carotid Artery Stenting].
No Shinkei Geka
; 44(7): 561-5, 2016 Jul.
Article
en Ja
| MEDLINE
| ID: mdl-27384116
Purpose: We present a novel, less invasive protection method for carotid artery stenting. Case presentation: A 67-year-old man presented with symptomatic severe left carotid artery stenosis. A transfemoral approach was dangerous because of an abdominal aortic aneurysm. A 6Fr Axcelguide Simmonds catheter was inserted into the right brachial artery, and advanced into the left common carotid artery. Next, a 6Fr Optimo 100-cm catheter was coaxially navigated into the left common carotid artery. A PercuSurge GuardWire 300-cm was coaxially navigated into the left external carotid artery. Under flow reversal with the 2 balloons, another PercuSurge GuardWire 300-cm was navigated into the distal left internal carotid artery through the lesion. After both PercuSurge GuardWire balloons were inflated, the 6Fr Optimo was deflated and retrieved using a catheter exchange technique. Then, under distal double-balloon protection, routine stenting was performed. Conclusions: This technique is safer and less invasive than previous methods, especially in cases with difficult femoral access and vulnerable carotid plaque.