Reliability of the Handgrip Strength Test in Elderly Subjects With Parkinson Disease.
Villafañe, Jorge H; Valdes, Kristin; Buraschi, Riccardo; Martinelli, Marco; Bissolotti, Luciano; Negrini, Stefano.
Afiliación
  • Villafañe JH; IRCCS Don Gnocchi Foundation, Milan, Italy.
  • Valdes K; Drexel University, Philadelphia, PA, USA.
  • Buraschi R; IRCCS Don Gnocchi Foundation, Milan, Italy.
  • Martinelli M; Casa di Cura Domus Salutis, Brescia, Italy.
  • Bissolotti L; Casa di Cura Domus Salutis, Brescia, Italy; LARIN: Laboratory of Neuromuscular Rehabilitation and Adapted Physical Activity, Brescia, Italy.
  • Negrini S; IRCCS Don Gnocchi Foundation, Milan, Italy; University of Brescia, Brescia, Italy.
Hand (N Y) ; 11(1): 54-8, 2016 Mar.
Article en En | MEDLINE | ID: mdl-27418890
ABSTRACT

BACKGROUND:

The handgrip strength test is widely used by clinicians; however, little has been investigated about its reliability when used in subjects with Parkinson disease (PD). The purpose of this study was to investigate the test-retest reliability of the handgrip strength test for subjects with PD.

METHODS:

The PD group consisted of 15 patients, and the control group consisted of 15 healthy subjects. Each patient performed 3 pain-free maximal isometric contractions on each hand on 2 occasions, 1 week apart. Intraclass correlation coefficient (ICC), standard error of measurement (SEM), and 95% limits of agreement (LOA) were calculated. The 2-way analysis of variance (ANOVA) was conducted to determine the differences between sides and groups.

RESULTS:

Test-retest reliability of measurements of grip strength was excellent for dominant (ICC = 0.97; P = .001) and non-dominant (ICC = 0.98; P = .001) hand of participant with PD and (ICC = 0.99; P = .001) and (ICC = 0.99; P = .001) respectively, of healthy group.

CONCLUSIONS:

The Jamar hand dynamometer had fair to excellent test-retest reliability to test grip strength in participants with PD.
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Idioma: En Revista: Hand (N Y) Año: 2016 Tipo del documento: Article País de afiliación: Italia