[Aortic valve replacement with stentless bioprosthesis: surgical technique and early outcomes].
Khirurgiia (Mosk)
; (5): 9-12, 2016.
Article
en Ru
| MEDLINE
| ID: mdl-27447013
ABSTRACT
AIM:
To evaluate prospectively the hemodynamic performance of «BiolAB Mono¼ stentless bioprosthesis implanted into aortic position. MATERIAL ANDMETHODS:
Twenty seven patients (mean age 71 (67; 73); 17 women) with severe aortic stenosis underwent, aortic valve replacement with «BioLAB Mono¼ stentless bioprosthesis from 2012 to 2014. The valves- were implanted into supraannular position using continuous polypropylene suture.RESULTS:
In the early postoperative period 1 patient (3.7%) died for acute heart failure. The mean aortic cross-clamping time was 81 (75; 90) min. Echocardiographic peak pressure gradient were 18 (16;23) mmHg (postoperative). There were no cases of valve dysfunction In early 'postoperative period. Level of thrombocytes recovered after 1 O days postoperatively.CONCLUSION:
«BioLAB Mono¼ aortic bioprosthesis implantation. is easy and reproducible. The valve has excellent hemodynamic performance ir;i early postoperative period.
Buscar en Google
Colección:
01-internacional
Base de datos:
MEDLINE
Asunto principal:
Válvula Aórtica
/
Estenosis de la Válvula Aórtica
/
Complicaciones Posoperatorias
/
Bioprótesis
/
Prótesis Valvulares Cardíacas
/
Implantación de Prótesis de Válvulas Cardíacas
/
Insuficiencia Cardíaca
Tipo de estudio:
Diagnostic_studies
/
Etiology_studies
/
Observational_studies
Límite:
Aged
/
Female
/
Humans
/
Male
País/Región como asunto:
Asia
Idioma:
Ru
Revista:
Khirurgiia (Mosk)
Año:
2016
Tipo del documento:
Article