Your browser doesn't support javascript.
loading
Reproducibility of Acoustic Radiation Force Impulse Imaging in Thyroid and Salivary Glands with Experienced and Inexperienced Examiners.
Hofauer, Benedikt; Mansour, Naglaa; Heiser, Clemens; Wirth, Markus; Straßen, Ulrich; Loeffelbein, Denys; Bas, Murat; Knopf, Andreas.
Afiliación
  • Hofauer B; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany. Electronic address: b.hofauer@tum.de.
  • Mansour N; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
  • Heiser C; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
  • Wirth M; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
  • Straßen U; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
  • Loeffelbein D; Cranio-Maxillo-Facial Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
  • Bas M; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
  • Knopf A; Otorhinolaryngology/Head and Neck Surgery, Klinikum rechts der Isar, Technical University Munich, Munich, Germany.
Ultrasound Med Biol ; 42(11): 2545-2552, 2016 11.
Article en En | MEDLINE | ID: mdl-27475926
ABSTRACT
Acoustic radiation force impulse (ARFI) imaging enables the sonographic measurement of tissue stiffness. The aim of this study was to evaluate if experience in ARFI imaging influences the reproducibility of ARFI imaging of the head and neck. Three experienced sonographers and three inexperienced sonographers performed ARFI imaging of thyroid, submandibular and parotid glands in 10 healthy volunteers. The examination was repeated after 2 wk. Ten single ARFI measurements were done in every gland. Inter-rater and intra-rater reliability was analyzed using the intra-class correlation coefficient (ICC). Moderate agreement was observed between experienced and inexperienced examiners (ICC = 0.46). In salivary glands, agreement was fair between the groups (ICC = 0.33), whereas in separate evaluations, inter-rater reliability in the submandibular glands was moderate (ICC = 0.52), and that in the parotid glands, only poor (ICC = 0.09). For ARFI imaging of the thyroid gland, there was moderate agreement between the groups (ICC = 0.50). The intra-rater reliability for the salivary and thyroid glands together and separately was strong in both groups. ARFI imaging of the thyroid and salivary glands did exhibit good reproducibility. ARFI imaging of the thyroid gland reached the highest levels of inter- and intra-observer agreement in both groups. ARFI imaging in salivary glands is only reproducible with experienced examiners.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glándulas Salivales / Glándula Tiroides / Competencia Clínica / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Ultrasound Med Biol Año: 2016 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Glándulas Salivales / Glándula Tiroides / Competencia Clínica / Diagnóstico por Imagen de Elasticidad Tipo de estudio: Diagnostic_studies Límite: Adult / Female / Humans / Male Idioma: En Revista: Ultrasound Med Biol Año: 2016 Tipo del documento: Article
...