Your browser doesn't support javascript.
loading
Biocompatibility and degradation of LAE442-based magnesium alloys after implantation of up to 3.5years in a rabbit model.
Angrisani, N; Reifenrath, J; Zimmermann, F; Eifler, R; Meyer-Lindenberg, A; Vano-Herrera, K; Vogt, C.
Afiliación
  • Angrisani N; NIFE - Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Department of Orthopedic Surgery, Hannover Medical School, Hannover, Germany. Electronic address: angrisani.nina@googlemail.com.
  • Reifenrath J; NIFE - Lower Saxony Centre for Biomedical Engineering, Implant Research and Development, Department of Orthopedic Surgery, Hannover Medical School, Hannover, Germany.
  • Zimmermann F; Institute of Inorganic Chemistry, Leibniz University of Hannover, Hannover, Germany.
  • Eifler R; Institute of Materials Science, Leibniz University of Hannover, Hannover, Germany.
  • Meyer-Lindenberg A; Clinic for Small Animal Surgery and Reproduction, Ludwig-Maximilians University, Munich, Germany.
  • Vano-Herrera K; Institute of Inorganic Chemistry, Leibniz University of Hannover, Hannover, Germany.
  • Vogt C; Institute of Inorganic Chemistry, Leibniz University of Hannover, Hannover, Germany.
Acta Biomater ; 44: 355-65, 2016 10 15.
Article en En | MEDLINE | ID: mdl-27497845
ABSTRACT
UNLABELLED Magnesium as basic implant material has long been the center of orthopedic research. Latest progress is achieved with a European certification and clinical use of a magnesium based compression screw. However, long term studies with implantation duration that exceed one year considerably do not exist. The present examinations analyzed the degradation progress from nine months to 3.5year after implantation of cylindrical pins into the medullary cavity of New Zealand White rabbits. Evaluation included clinical assessment, in vivo µ-computed tomography, analysis of the implants by three-point-bending and examination of the adjacent tissue by means of histology and of inner organs by mass- and optical emission spectrometry using inductively coupled plasma. Clinical acceptance was without objections in all animals. Immoderate reaction of the surrounding bone could be found in neither of the applied techniques. While in vivo µ-computed tomography showed a very slow degradation rate up to 72weeks, three-point-bending revealed a percentage loss of F(max) of 41.1% for implants after 9months implantation and 88.47% for the implant after 3.5years implantation. Although the total amounts of RE detected in the inner organs were very low, the organs of rabbits with LAE442 cylinders showed 10-20-fold increased concentrations of the alloying elements lanthanum, cerium, neodymium and praseodymium compared to animals without any implanted material. STATEMENT OF

SIGNIFICANCE:

This is the first animal study investigating the degradation process of a magnesium alloy in vivo for up to 3.5years. Currently available data from different other in vivo studies cover only implantation durations up to one year. Therefore, the analysis of these long-time effects in the present study is highly significant and of great interest. Comprehensive outcome achieved by different techniques was assessed. The degradation process was slow and homogenous. Maximum applied force (F(max)) reduced by 41.1% for implants after 9months and by 88.47% for the implant after 3.5years implantation. Total amounts of RE detected in the inner organs were very low; the organs of rabbits with LAE442 cylinders showed 10-20-fold increased concentrations.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Implantes Experimentales / Aleaciones / Magnesio Límite: Animals Idioma: En Revista: Acta Biomater Año: 2016 Tipo del documento: Article Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Implantes Experimentales / Aleaciones / Magnesio Límite: Animals Idioma: En Revista: Acta Biomater Año: 2016 Tipo del documento: Article Pais de publicación: ENGLAND / ESCOCIA / GB / GREAT BRITAIN / INGLATERRA / REINO UNIDO / SCOTLAND / UK / UNITED KINGDOM