Your browser doesn't support javascript.
loading
Electroactive and biocompatible functionalization of graphene for the development of biosensing platforms.
Halder, Arnab; Zhang, Minwei; Chi, Qijin.
Afiliación
  • Halder A; Department of Chemistry, Technical University of Denmark, DK-2800 Kongens Lyngby, Denmark.
  • Zhang M; Department of Chemistry, Technical University of Denmark, DK-2800 Kongens Lyngby, Denmark.
  • Chi Q; Department of Chemistry, Technical University of Denmark, DK-2800 Kongens Lyngby, Denmark. Electronic address: cq@kemi.dtu.dk.
Biosens Bioelectron ; 87: 764-771, 2017 Jan 15.
Article en En | MEDLINE | ID: mdl-27649333
Design and synthesis of low-cost, highly stable, electroactive and biocompatible material is one of the key steps for the advancement of electrochemical biosensing systems. To this end, we have explored a facile way for the successful synthesis of redox active and bioengineering of reduced graphene oxide (RGO) for the development of versatile biosensing platform. A highly branched polymer (PEI) is used for reduction and simultaneous derivation of graphene oxide (GO) to form a biocompatible polymeric matrix on RGO nanosheet. Ferrocene redox moieties are then wired onto RGO nanosheets through the polymer matrix. The as-prepared functional composite is electrochemically active and enables to accommodate enzymes stably. For proof-of-concept studies, two crucial redox enzymes for biosensors (i.e. cholesterol oxidase and glucose oxidase) are targeted. The enzyme integrated and RGO supported biosensing hybrid systems show high stability, excellent selectivity, good reproducibility and fast sensing response. As measured, the detection limit of the biosensors for glucose and cholesterol is 5µM and 0.5µM (S/N=3), respectively. The linear response range of the biosensor is from 0.1 to 15.5mM for glucose and from 2.5 to 25µM for cholesterol. Furthermore, this biosensing platform shows good anti-interference ability and reasonable stability. The nanohybrid biosensing materials can be combined with screen-printed electrodes, which are successfully used for measuring the glucose and cholesterol level of real human serum samples.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Glucemia / Técnicas Biosensibles / Colesterol / Nanoestructuras / Grafito Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Materiales Biocompatibles / Glucemia / Técnicas Biosensibles / Colesterol / Nanoestructuras / Grafito Tipo de estudio: Evaluation_studies / Prognostic_studies Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Dinamarca Pais de publicación: Reino Unido