Your browser doesn't support javascript.
loading
Reliability testing of the Larsen and Sharp classifications for rheumatoid arthritis of the elbow.
Jew, Nicholas B; Hollins, Anthony M; Mauck, Benjamin M; Smith, Richard A; Azar, Frederick M; Miller, Robert H; Throckmorton, Thomas W.
Afiliación
  • Jew NB; University of Tennessee-Campbell Clinic, Department of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN, USA.
  • Hollins AM; Memphis Shoulder & Orthopedic Surgery, Memphis, TN, USA.
  • Mauck BM; University of Tennessee-Campbell Clinic, Department of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN, USA.
  • Smith RA; University of Tennessee-Campbell Clinic, Department of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN, USA.
  • Azar FM; University of Tennessee-Campbell Clinic, Department of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN, USA.
  • Miller RH; University of Tennessee-Campbell Clinic, Department of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN, USA.
  • Throckmorton TW; University of Tennessee-Campbell Clinic, Department of Orthopaedic Surgery and Biomedical Engineering, Memphis, TN, USA. Electronic address: tthrockmorton@campbellclinic.com.
J Shoulder Elbow Surg ; 26(1): 140-143, 2017 Jan.
Article en En | MEDLINE | ID: mdl-27727050
BACKGROUND: Two popular systems for classifying rheumatoid arthritis affecting the elbow are the Larsen and Sharp schemes. To our knowledge, no study has investigated the reliability of these 2 systems. We compared the intraobserver and interobserver agreement of the 2 systems to determine whether one is more reliable than the other. METHODS: The radiographs of 45 patients diagnosed with rheumatoid arthritis affecting the elbow were evaluated. Anteroposterior and lateral radiographs were deidentified and distributed to 6 evaluators (4 fellowship-trained upper extremity surgeons and 2 orthopedic trainees). Each evaluator graded all 45 radiographs according to the Larsen and Sharp scoring methods on 2 occasions, at least 2 weeks apart. RESULTS: Overall intraobserver reliability was 0.93 (95% confidence interval [CI], 0.90-0.95) for the Larsen system and 0.92 (95% CI, 0.86-0.96) for the Sharp classification, both indicating substantial agreement. Overall interobserver reliability was 0.70 (95% CI, 0.60-0.80) for the Larsen classification and 0.68 (95% CI, 0.54-0.81) for the Sharp system, both indicating good agreement. There were no significant differences in the intraobserver or interobserver reliability of the systems overall and no significant differences in reliability between attending surgeons and trainees for either classification system. CONCLUSION: The Larsen and Sharp systems both show substantial intraobserver reliability and good interobserver agreement for the radiographic classification of rheumatoid arthritis affecting the elbow. Differences in training level did not result in substantial variances in reliability for either system. We conclude that both systems can be reliably used to evaluate rheumatoid arthritis of the elbow by observers of varying training levels.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artritis Reumatoide / Articulación del Codo Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Shoulder Elbow Surg Asunto de la revista: ORTOPEDIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Artritis Reumatoide / Articulación del Codo Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Shoulder Elbow Surg Asunto de la revista: ORTOPEDIA Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos Pais de publicación: Estados Unidos