Multi-slice SPECT/CT vs. lymphoscintigraphy and intraoperative gamma ray probe for sentinel node mapping in HNSCC.
Meerwein, C M; Sekine, T; Veit-Haibach, P; Bredell, M G; Huber, G F; Huellner, M W.
Afiliación
  • Meerwein CM; Department of Otorhinolaryngology, University Hospital Zurich, Zurich, Switzerland. christian.meerwein@usz.ch.
  • Sekine T; University of Zurich, Zurich, Switzerland. christian.meerwein@usz.ch.
  • Veit-Haibach P; Division of Otorhinolaryngology, Frauenklinikstrasse 24, 8091, Zurich, Switzerland. christian.meerwein@usz.ch.
  • Bredell MG; Department of Nuclear Medicine, University Hospital Zurich, Zurich, Switzerland.
  • Huber GF; University of Zurich, Zurich, Switzerland.
  • Huellner MW; Department of Radiology, Nippon Medical School, Tokyo, Japan.
Eur Arch Otorhinolaryngol ; 274(3): 1633-1642, 2017 Mar.
Article en En | MEDLINE | ID: mdl-27837418
To assess the diagnostic potential of multi-slice single-photon emission computed tomography/computed tomography (SPECT/CT) for preoperative sentinel node (SN) mapping in early stage head and neck squamous cell carcinoma (HNSCC). Retrospective case-control study including data of consecutive HNSCC patients treated between November 2011 and December 2015. The diagnostic accuracy of multi-slice SPECT/CT was assessed with regard to the gold standard intraoperative gamma ray detection probe, using McNemar's test and calculating the area under the ROC curve. Additionally, the hot spot yield of SPECT/CT and planar lymphoscintigraphy (LS) was compared. Compared to the intraoperative gold standard, SPECT/CT showed an overall positive predictive value of 60.3% [confidence interval (CI) 46.6-73.0%)], a negative predictive value of 96.3% (CI 93.6-98.1%), and an accuracy of 90.8% (CI 89.1-92.4%). SPECT/CT detected more hot spots than LS and provided detailed anatomical information as well as relevant additional findings with potential impact on further patient management. Sentinel lymph node biopsy proved to be a reliable and safe procedure with an excellent SN excision rate (97%). Multi-slice SPECT/CT is a highly accurate diagnostic test and matches the gold standard intraoperative gamma ray detection probe.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Carcinoma de Células Escamosas / Biopsia del Ganglio Linfático Centinela / Linfocintigrafia / Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único / Neoplasias de Cabeza y Cuello Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Arch Otorhinolaryngol Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Alemania

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Carcinoma de Células Escamosas / Biopsia del Ganglio Linfático Centinela / Linfocintigrafia / Tomografía Computarizada por Tomografía Computarizada de Emisión de Fotón Único / Neoplasias de Cabeza y Cuello Tipo de estudio: Observational_studies / Prognostic_studies / Risk_factors_studies Límite: Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Eur Arch Otorhinolaryngol Asunto de la revista: OTORRINOLARINGOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Suiza Pais de publicación: Alemania