Your browser doesn't support javascript.
loading
Measuring core temperature using the proprietary application and thermo-smartphone adapter.
Darocha, Tomasz; Majkowski, Jacek; Sanak, Tomasz; Podsiadlo, Pawel; Kosinski, Sylweriusz; Salapa, Kinga; Mazur, Piotr; Zietkiewicz, Miroslaw; Galazkowski, Robert; Krzych, Lukasz; Drwila, Rafal.
Afiliación
  • Darocha T; Severe Accidental Hypothermia Center, Kraców, Poland. tomekdarocha@wp.pl.
  • Majkowski J; Department of Anesthesiology and Intensive Care, John Paul II Hospital, Severe Accidental Hypothermia Center, 80 Pradnicka St., 31-202, Kraców, Poland. tomekdarocha@wp.pl.
  • Sanak T; Heart for Life Foundation, Kraców, Poland. tomekdarocha@wp.pl.
  • Podsiadlo P; Institute of Cardiology, Jagiellonian University Medical College, Kraców, Poland. tomekdarocha@wp.pl.
  • Kosinski S; Polish Medical Air Rescue, Warsaw, Poland. tomekdarocha@wp.pl.
  • Salapa K; Heart for Life Foundation, Kraców, Poland.
  • Mazur P; Heart for Life Foundation, Kraców, Poland.
  • Zietkiewicz M; Department of Disaster Medicine and Emergency Care, Jagiellonian University Medical College, Kraców, Poland.
  • Galazkowski R; Department of Combat Medicine, Military Institute, Warsaw, Poland.
  • Krzych L; Polish Medical Air Rescue, Warsaw, Poland.
  • Drwila R; Polish Society for Mountain Medicine and Rescue, Szczyrk, Poland.
J Clin Monit Comput ; 31(6): 1299-1304, 2017 Dec.
Article en En | MEDLINE | ID: mdl-28013421
ABSTRACT
Fast and accurate measurement of core body temperature is crucial for accidental hypothermia treatment. We have developed a novel light and small adapter to the headset jack of a mobile phone based on Android. It has been applied to measure temperature and set up automatic notifications (e.g. Global Positioning System coordinates to emergency services dispatcher, ECMO coordinator). Its validity was confirmed in comparison with Vital Signs Monitor Spacelabs Healthcare Elance 93300 as a reference method, in a series of 260 measurements in the temperature range of 10-42 °C. Measurement repeatability was verified in a battery of 600 measurements (i.e. 100 readings at three points of 10, 25, 42 °C for both esophageal and tympanic catheters). Inter-method difference of ≤0.5 °C was found for 98.5% for esophageal catheter and 100% for tympanic catheter measurements, with concordance correlation coefficient of 0.99 for both. The readings were almost completely repeatable with water bath measurements (difference of ≤0.5 °C in 10 °C 100% for both catheters; in 25 °C 99% for esophageal catheter and 100% tympanic catheter; in 42 °C 100% for both catheters). This lightweight adapter attached to smartphone and standard disposable probes is a promising tool to be applied on-site for temperature measurement in patients at risk of hypothermia.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Temperatura Corporal / Teléfono Inteligente / Monitoreo Fisiológico Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Polonia

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Temperatura Corporal / Teléfono Inteligente / Monitoreo Fisiológico Tipo de estudio: Diagnostic_studies Límite: Humans Idioma: En Revista: J Clin Monit Comput Asunto de la revista: INFORMATICA MEDICA / MEDICINA Año: 2017 Tipo del documento: Article País de afiliación: Polonia