Micro-electromechanical film bulk acoustic sensor for plasma and whole blood coagulation monitoring.
Chen, Da; Song, Shuren; Ma, Jilong; Zhang, Zhen; Wang, Peng; Liu, Weihui; Guo, Qiuquan.
Afiliación
  • Chen D; Mine Disaster Prevention and Control Key Laboratory of Education Ministry of China, Shandong University of Science and Technology, Qingdao 266590, China; College of Electronics, Communications, and Physics, Shandong University of Science and Technology, Qingdao 266590, PR China. Electronic address:
  • Song S; College of Electronics, Communications, and Physics, Shandong University of Science and Technology, Qingdao 266590, PR China.
  • Ma J; College of Electronics, Communications, and Physics, Shandong University of Science and Technology, Qingdao 266590, PR China.
  • Zhang Z; College of Electronics, Communications, and Physics, Shandong University of Science and Technology, Qingdao 266590, PR China.
  • Wang P; College of Electronics, Communications, and Physics, Shandong University of Science and Technology, Qingdao 266590, PR China.
  • Liu W; College of Electronics, Communications, and Physics, Shandong University of Science and Technology, Qingdao 266590, PR China.
  • Guo Q; Mechanical & Materials Engineering, Western University, London, Ontario, Canada, N6A 3K7. Electronic address: qguo29@uwo.ca.
Biosens Bioelectron ; 91: 465-471, 2017 May 15.
Article en En | MEDLINE | ID: mdl-28068607
ABSTRACT
Monitoring blood coagulation is an important issue in the surgeries and the treatment of cardiovascular diseases. In this work, we reported a novel strategy for the blood coagulation monitoring based on a micro-electromechanical film bulk acoustic resonator. The resonator was excited by a lateral electric field and operated under the shear mode with a frequency of 1.9GHz. According to the apparent step-ladder curves of the frequency response to the change of blood viscoelasticity, the coagulation time (prothrombin time) and the coagulation kinetics were measured with the sample consumption of only 1µl. The procoagulant activity of thromboplastin and the anticoagulant effect of heparin on the blood coagulation process were illustrated exemplarily. The measured prothrombin times showed a good linear correlation with R2=0.99969 and a consistency with the coefficient of variation less than 5% compared with the commercial coagulometer. The proposed film bulk acoustic sensor, which has the advantages of small size, light weight, low cost, simple operation and little sample consumption, is a promising device for miniaturized, online and automated analytical system for routine diagnostics of hemostatic status and personal health monitoring.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Acústica / Coagulación Sanguínea / Pruebas de Coagulación Sanguínea / Sistemas Microelectromecánicos Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2017 Tipo del documento: Article

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Acústica / Coagulación Sanguínea / Pruebas de Coagulación Sanguínea / Sistemas Microelectromecánicos Límite: Humans Idioma: En Revista: Biosens Bioelectron Asunto de la revista: BIOTECNOLOGIA Año: 2017 Tipo del documento: Article
...