Your browser doesn't support javascript.
loading
Application of Computed Tomography Processed by Picture Archiving and Communication Systems in the Diagnosis of Acute Achilles Tendon Rupture.
Xue, Hai-Peng; Liu, Xin-Wei; Tian, Jing; Xie, Bing; Yang, Chao; Zhang, Hao; Zhou, Da-Peng.
Afiliación
  • Xue HP; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
  • Liu XW; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
  • Tian J; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
  • Xie B; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
  • Yang C; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
  • Zhang H; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
  • Zhou DP; Department of Orthopedics, General Hospital of Shenyang Military Area Command of Chinese PLA, Rescue Center of Severe Wound and Trauma of Chinese PLA, Shenyang, Liaoning 110016, China.
Biomed Res Int ; 2016: 6043638, 2016.
Article en En | MEDLINE | ID: mdl-28078295
ABSTRACT
The applications of CT examination in the diagnosis of the acute Achilles tendon rupture (AATR) were investigated. A total of 36 patients with suspected acute Achilles tendon rupture were tested using physical examination, ultrasound, and 3DCT scanning, respectively. Then, surgery was performed for the patients who showed positive result in at least two of the three tests for AATR. 3DVR, MPR, and the other CT scan image processing and diagnosis were conducted in PACS (picture archiving and communication system). PACS was also used to measure the length of distal broken ends of the Achilles tendon (AT) to tendon calcaneal insertion. Our study indicated that CT has the highest accuracy in diagnosis of acute Achilles tendon complete rupture. The length measurement is matched between PACS and those actually measured in operation. CT not only demonstrates more details directly in three dimensions especially with the rupture involved calcaneal insertion flap but also locates the rupture region for percutaneous suture by measuring the length of distal stump in PACS without the effect of the position of ankle. The accuracy of CT diagnosis for Achilles tendon partial rupture is yet to be studied.
Asunto(s)

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rotura / Tendón Calcáneo / Traumatismos de los Tendones / Tomografía Computarizada por Rayos X Tipo de estudio: Diagnostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Biomed Res Int Año: 2016 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Rotura / Tendón Calcáneo / Traumatismos de los Tendones / Tomografía Computarizada por Rayos X Tipo de estudio: Diagnostic_studies Límite: Adolescent / Adult / Aged / Aged80 / Female / Humans / Male / Middle aged Idioma: En Revista: Biomed Res Int Año: 2016 Tipo del documento: Article País de afiliación: China