Your browser doesn't support javascript.
loading
Preparation of a poly(styrene-co-DPHA-co-EDMA) monolith and its application for the separation of small molecules and biomacromolecules by HPLC.
Wang, Xixi; Li, Xueying; Jiang, Xiaoya; Dong, Peipei; Liu, Haiyan; Bai, Ligai; Yan, Hongyuan.
Afiliación
  • Wang X; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China.
  • Li X; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China.
  • Jiang X; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China.
  • Dong P; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China.
  • Liu H; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China. Electronic address: lhy1610@126.com.
  • Bai L; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China.
  • Yan H; College of Pharmaceutical Sciences, Hebei University, Baoding 071002, China; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis, Ministry of Education, Baoding 071002, China.
Talanta ; 165: 339-345, 2017 Apr 01.
Article en En | MEDLINE | ID: mdl-28153264
ABSTRACT
A high performance liquid chromatography (HPLC) monolithic column was prepared by redox polymerization of styrene, dipentaerythritol hexaacrylate (DPHA) and ethylene glycol dimethacrylate (EDMA) in a porogen system of n-propanol/PEG400. The monolith was characterized by scanning electron microscopy (SEM), mercury intrusion porosimetry (MIP) and the results indicated that the monolith had a stable and homogeneous structure. The porosity of the monolithic column was 75.86% and average pore diameter was 2.1µm. Several alkylbenzenes and anilines were used to evaluate the column performance in terms of hydrophobicity. Then the column was applied to separate small molecules including phytosterol and BSA tryptic digest. Finally, five standard proteins, egg white and plasma were separated respectively and high separation capacity of protein was obtained.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fragmentos de Péptidos / Fitosteroles / Polietilenglicoles / Proteínas / Cromatografía Líquida de Alta Presión / Estireno / Metacrilatos Límite: Animals / Humans Idioma: En Revista: Talanta Año: 2017 Tipo del documento: Article País de afiliación: China

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fragmentos de Péptidos / Fitosteroles / Polietilenglicoles / Proteínas / Cromatografía Líquida de Alta Presión / Estireno / Metacrilatos Límite: Animals / Humans Idioma: En Revista: Talanta Año: 2017 Tipo del documento: Article País de afiliación: China