ABSTRACT
This study was conducted to determine the effect of testing parameters on the in vitro activity of gepotidacin, a new triazaacenaphthylene antibacterial agent for the treatment of conventional and biothreat pathogens. CLSI methods, and variations of those methods, were used to test 10 Staphylococcus aureus, 10 Streptococcus pneumoniae, 10 Haemophilus influenzae, and 5 Escherichia coli isolates by MIC and 30 S. aureus, 15 S. pneumoniae, and 15 S. pyogenes isolates by disk diffusion (DD) methods. Levofloxacin and linezolid were tested as comparator agents for MIC and DD methods, respectively. Broth microdilution (BMD), macrodilution (MD), and agar dilution (AD) methods were compared. Variations in media, temperature, incubation time, CO2 level, and inoculum concentration were tested by all methods, and variations in pH, calcium, magnesium, zinc, potassium, thymidine, and polysorbate 80 levels were tested by BMD and DD. The addition of albumin, serum, and lung surfactant was studied by BMD. The variables that impacted the results the most were high inoculum and pH 5.5 (no growth of H. influenzae and S. pneumoniae by BMD). Gepotidacin AD MIC levels were increased and disk zone diameters were decreased for all species in 10% CO2 incubation. The following variables had a minimal effect on gepotidacin

results:

pH, agar method, atmospheric condition, temperature, and addition of serum and albumin for broth methods. There were also some slight differences in gepotidacin disk results between disk manufacturers and some agar types and also with potassium and thymidine for S. pneumoniae For all other variations, gepotidacin MIC and disk results were considered comparable to reference results.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bacterias / Pruebas de Sensibilidad Microbiana / Compuestos Heterocíclicos con 3 Anillos / Acenaftenos / Antibacterianos Tipo de estudio: Evaluation_studies Idioma: En Revista: J Clin Microbiol Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Bacterias / Pruebas de Sensibilidad Microbiana / Compuestos Heterocíclicos con 3 Anillos / Acenaftenos / Antibacterianos Tipo de estudio: Evaluation_studies Idioma: En Revista: J Clin Microbiol Año: 2017 Tipo del documento: Article País de afiliación: Estados Unidos
...