Your browser doesn't support javascript.
loading
Conceptual design and implantation of an external fixator with improved mobility for knee rehabilitation.
Gatti, Gianluca.
Afiliación
  • Gatti G; a Department of Mechanical, Energy and Management Engineering , University of Calabria , Arcavacata di Rende (CS) , Italy.
Comput Methods Biomech Biomed Engin ; 20(8): 884-892, 2017 Jun.
Article en En | MEDLINE | ID: mdl-28332404
A hinged external fixator is used to allow early knee rehabilitation in case of injury or trauma, as an alternative approach to immobilization. It is mainly adopted for the treatment of dislocations, which involve tearing of the ligaments, and it basically consists of two links connected to each other by a revolute joint. Each link is fixed to the femur and tibia via pin fixation, and the revolute joint is approximately aligned to the knee flexion-extension (FE) axis. The advantage in its implantation is to protect ligament reconstruction, while allowing for an aggressive rehabilitation. Traditional fixators only accommodate the functional flexion movement in a limited range, i.e. where the anatomical movement is closer to a planar circular trajectory. This paper presents the conceptual design and implantation procedure of a double-axis fixator, which accommodates both FE and longitudinal internal-external rotation. The procedure is based on accurate knee kinematics measurements and on computer-aided multibody simulations to assist clinicians in the implantation. An experimental test is presented using an artificial knee, and guidelines are given for in vitro studies. The proposed technique may allow for a better understanding of knee kinematics and have the potential advantage to increase the range of motion in postoperative rehabilitation.
Asunto(s)
Palabras clave

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fijadores Externos / Rango del Movimiento Articular / Implantación de Prótesis / Procedimientos de Cirugía Plástica / Articulación de la Rodilla Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Comput Methods Biomech Biomed Engin Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Reino Unido

Texto completo: 1 Colección: 01-internacional Base de datos: MEDLINE Asunto principal: Fijadores Externos / Rango del Movimiento Articular / Implantación de Prótesis / Procedimientos de Cirugía Plástica / Articulación de la Rodilla Tipo de estudio: Guideline Límite: Humans Idioma: En Revista: Comput Methods Biomech Biomed Engin Asunto de la revista: ENGENHARIA BIOMEDICA / FISIOLOGIA Año: 2017 Tipo del documento: Article País de afiliación: Italia Pais de publicación: Reino Unido